Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsSIC | 3084 | Plastics Pipe |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NV0067 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,845 | $197 | Not Implemented |
NV0067 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $419 | $18 | Not Implemented |
NV0067 # 03 Y:1996 | 03 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,487 | $45 | Not Implemented |
NV0067 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $2,646 | $1,085 | Not Implemented |
NV0067 # 05 Y:1996 | 05 | 1996 | USE POWER DURING OFF-PEAK PERIODS | $14,885 | $0 | Implemented |
NV0067 # 06 Y:1996 | 06 | 1996 | OPTIMIZE PLANT POWER FACTOR | $1,021 | $0 | Implemented |
NV0067 # 07 Y:1996 | 07 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,095 | $0 | Implemented |
OR0280 # 05 Y:1996 | 05 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $174 | $0 | Not Implemented |
OR0280 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,576 | $0 | Implemented |
OR0280 # 02 Y:1996 | 02 | 1996 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $1,940 | $2,500 | Not Implemented |
OR0280 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,986 | $15,828 | Implemented |
OR0280 # 04 Y:1996 | 04 | 1996 | OPTIMIZE PLANT POWER FACTOR | $2,830 | $9,700 | Not Implemented |
IA0157 # 03 Y:1996 | 03 | 1996 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $945 | $260 | Not Implemented |
IA0157 # 04 Y:1996 | 04 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $971 | $2,560 | Implemented |
IA0157 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $697 | $222 | Implemented |
IA0157 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $623 | $160 | Implemented |
IA0157 # 07 Y:1996 | 07 | 1996 | OPTIMIZE PLANT POWER FACTOR | $11,884 | $22,134 | Implemented |
IA0157 # 08 Y:1996 | 08 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $6,291 | $0 | Not Implemented |
IA0157 # 09 Y:1996 | 09 | 1996 | IMPROVE HANDLING PRACTICES | $5,008 | $2,000 | Implemented |
IA0157 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $465 | $516 | Implemented |
IA0157 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,211 | $6,599 | Implemented |
AR0096 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,513 | $477 | Implemented |
AR0096 # 06 Y:1996 | 06 | 1996 | MAINTAIN MACHINES TO REDUCE LEAKS | $2,580 | $100 | Implemented |
AR0096 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,100 | $70 | Implemented |
AR0096 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $608 | $80 | Implemented |