Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
397
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0685 # 02 Y:2000 | 02 | 2000 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $13,650 | $11,650 | Implemented |
GT0685 # 03 Y:2000 | 03 | 2000 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $714 | $500 | Implemented |
GT0685 # 04 Y:2000 | 04 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $28,840 | $7,000 | Implemented |
GT0685 # 05 Y:2000 | 05 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,955 | $0 | Implemented |
UF0232 # 02 Y:1999 | 02 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,006 | $60 | Implemented |
UF0232 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,521 | $1,500 | Implemented |
UF0232 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $1,539 | $834 | Implemented |
UF0232 # 05 Y:1999 | 05 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,215 | $0 | Implemented |
UF0232 # 06 Y:1999 | 06 | 1999 | USE PLASTIC PALLETS INSTEAD OF WOOD | $25,200 | $14,070 | Implemented |
UF0232 # 08 Y:1999 | 08 | 1999 | $15,848 | $75,000 | Implemented | |
GT0669 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,756 | $60,795 | Implemented |
GT0669 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $641 | $1,250 | Implemented |
GT0669 # 03 Y:1999 | 03 | 1999 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,935 | $6,800 | Implemented |
GT0669 # 05 Y:1999 | 05 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $113,437 | $0 | Implemented |
GT0669 # 06 Y:1999 | 06 | 1999 | KEEP EQUIPMENT CLEAN | $2,200 | $1,000 | Implemented |
GT0669 # 07 Y:1999 | 07 | 1999 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $8,844 | $32,000 | Implemented |
GT0669 # 08 Y:1999 | 08 | 1999 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $550 | $200 | Implemented |
UF0219 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,814 | $2,600 | Implemented |
UF0219 # 06 Y:1999 | 06 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $820 | $1,200 | Implemented |
MA0433 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,317 | $3,950 | Implemented |
AS0243 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $7,800 | $80 | Implemented |
KU0508 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,850 | $5,030 | Implemented |
KU0508 # 02 Y:1998 | 02 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,900 | $7,180 | Implemented |
KU0508 # 03 Y:1998 | 03 | 1998 | INSTALL OCCUPANCY SENSORS | $470 | $350 | Implemented |
KU0508 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $440 | $100 | Implemented |