Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
884
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0231 # 07 Y:2003 | 07 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,254 | $8,386 | Not Implemented |
MS0231 # 08 Y:2003 | 08 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $3,584 | $3,456 | Implemented |
MS0231 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $995 | $2,905 | Not Implemented |
MS0231 # 10 Y:2003 | 10 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $152 | $119 | Implemented |
MS0231 # 11 Y:2003 | 11 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $120 | $10 | Implemented |
SD0304 # 01 Y:2002 | 01 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $258,459 | $242,000 | Not Implemented |
SD0304 # 02 Y:2002 | 02 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $362,272 | $628,750 | Not Implemented |
SD0304 # 03 Y:2002 | 03 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $43,804 | $29,000 | Not Implemented |
SD0304 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,788 | $39,000 | Not Implemented |
SD0304 # 05 Y:2002 | 05 | 2002 | USE PHOTOCELL CONTROLS | $21,520 | $3,000 | Not Implemented |
SD0304 # 06 Y:2002 | 06 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,050 | $0 | Not Implemented |
SD0304 # 07 Y:2002 | 07 | 2002 | INSULATE BARE EQUIPMENT | $12,405 | $2,120 | Not Implemented |
SD0304 # 08 Y:2002 | 08 | 2002 | INSTALL OCCUPANCY SENSORS | $2,591 | $600 | Not Implemented |
SD0304 # 09 Y:2002 | 09 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $10,400 | $15,000 | Not Implemented |
SD0304 # 10 Y:2002 | 10 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,500 | $2,500 | Not Implemented |
LM0032 # 01 Y:2002 | 01 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,509 | $0 | Implemented |
LM0032 # 02 Y:2002 | 02 | 2002 | INSTALL SKYLIGHTS | $5,597 | $10,400 | Not Implemented |
LM0032 # 03 Y:2002 | 03 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,278 | $576 | Not Implemented |
LM0032 # 04 Y:2002 | 04 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $306 | $160 | Implemented |
LM0032 # 05 Y:2002 | 05 | 2002 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,275 | $2,572 | Implemented |
LM0032 # 06 Y:2002 | 06 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $78,909 | $130,043 | Implemented |
LM0032 # 07 Y:2002 | 07 | 2002 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $22,049 | $60,000 | Implemented |
TA0027 # 01 Y:2002 | 01 | 2002 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $42,200 | $85,300 | Not Implemented |
TA0027 # 02 Y:2002 | 02 | 2002 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $39,800 | $7,500 | Implemented |
TA0027 # 03 Y:2002 | 03 | 2002 | INSULATE BARE EQUIPMENT | $3,000 | $268 | Not Implemented |