Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
46
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0232 # 08 Y:1999 | 08 | 1999 | $15,848 | $75,000 | Implemented | |
UF0232 # 07 Y:1999 | 07 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $262,532 | $850,000 | Not Implemented |
UF0232 # 06 Y:1999 | 06 | 1999 | USE PLASTIC PALLETS INSTEAD OF WOOD | $25,200 | $14,070 | Implemented |
UF0232 # 05 Y:1999 | 05 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,215 | $0 | Implemented |
UF0232 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $1,539 | $834 | Implemented |
UF0232 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,521 | $1,500 | Implemented |
UF0232 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $192,386 | $82,242 | Not Implemented |
UF0232 # 02 Y:1999 | 02 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,006 | $60 | Implemented |
GT0669 # 06 Y:1999 | 06 | 1999 | KEEP EQUIPMENT CLEAN | $2,200 | $1,000 | Implemented |
GT0669 # 09 Y:1999 | 09 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $108,000 | $100,000 | Not Implemented |
GT0669 # 08 Y:1999 | 08 | 1999 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $550 | $200 | Implemented |
GT0669 # 07 Y:1999 | 07 | 1999 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $8,844 | $32,000 | Implemented |
GT0669 # 05 Y:1999 | 05 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $113,437 | $0 | Implemented |
GT0669 # 04 Y:1999 | 04 | 1999 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $10,870 | $7,700 | Not Implemented |
GT0669 # 03 Y:1999 | 03 | 1999 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,935 | $6,800 | Implemented |
GT0669 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $641 | $1,250 | Implemented |
GT0669 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,756 | $60,795 | Implemented |
SF0173 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $358 | $451 | Not Implemented |
SF0173 # 08 Y:1999 | 08 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $112,000 | $49,860 | Not Implemented |
SF0173 # 07 Y:1999 | 07 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $3,500 | $164 | Not Implemented |
SF0173 # 06 Y:1999 | 06 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $56,000 | $0 | Not Implemented |
SF0173 # 05 Y:1999 | 05 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $14,305 | $14,475 | Not Implemented |
SF0173 # 04 Y:1999 | 04 | 1999 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,455 | $7,000 | Not Implemented |
SF0173 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $423 | $1,200 | Not Implemented |
SF0173 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $269 | $506 | Not Implemented |