Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
990
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0809 # 13 Y:2009 | 13 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,348 | $1,703 | Implemented |
UD0809 # 14 Y:2009 | 14 | 2009 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,678 | $5,467 | Not Implemented |
UD0809 # 15 Y:2009 | 15 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $685 | $0 | Not Implemented |
UD0809 # 16 Y:2009 | 16 | 2009 | DISCONNECT BALLASTS | $532 | $0 | Not Implemented |
UD0809 # 17 Y:2009 | 17 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $414 | $0 | Implemented |
UD0809 # 18 Y:2009 | 18 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $363 | $0 | Not Implemented |
UD0809 # 19 Y:2009 | 19 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $181 | $500 | Not Implemented |
UD0792 # 01 Y:2009 | 01 | 2009 | Wind Power | $1,103,774 | $5,850,000 | Not Implemented |
UD0792 # 02 Y:2009 | 02 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,846 | $92,500 | Not Implemented |
UD0792 # 03 Y:2009 | 03 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,922 | $4,000 | Not Implemented |
UD0792 # 04 Y:2009 | 04 | 2009 | INSULATE BARE EQUIPMENT | $12,029 | $2,640 | Not Implemented |
UD0792 # 05 Y:2009 | 05 | 2009 | OPTIMIZE PLANT POWER FACTOR | $4,640 | $12,000 | Not Implemented |
UD0792 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,270 | $8,700 | Not Implemented |
UD0792 # 07 Y:2009 | 07 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,350 | $1,000 | Not Implemented |
UD0792 # 08 Y:2009 | 08 | 2009 | INSULATE BARE EQUIPMENT | $2,010 | $900 | Not Implemented |
UD0792 # 09 Y:2009 | 09 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,247 | $1,000 | Not Implemented |
UD0792 # 10 Y:2009 | 10 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,067 | $5,170 | Not Implemented |
UD0792 # 11 Y:2009 | 11 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,050 | $0 | Not Implemented |
UD0789 # 01 Y:2009 | 01 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $35,682 | $25,000 | Not Implemented |
UD0789 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $33,134 | $0 | Implemented |
UD0789 # 03 Y:2009 | 03 | 2009 | INSULATE BARE EQUIPMENT | $32,063 | $3,630 | Not Implemented |
UD0789 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,092 | $46,620 | Implemented |
UD0789 # 05 Y:2009 | 05 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $16,900 | $500 | Implemented |
UD0789 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,888 | $26,100 | Not Implemented |
UD0789 # 07 Y:2009 | 07 | 2009 | OPTIMIZE PLANT POWER FACTOR | $12,305 | $92,000 | Not Implemented |