Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
562
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KG0049 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $248 | $300 | Implemented |
KG0049 # 06 Y:1996 | 06 | 1996 | TREAT AND REUSE RINSE WATERS | $2,707 | $3,000 | Implemented |
KG0049 # 07 Y:1996 | 07 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $44,609 | $2,000 | Implemented |
KG0049 # 08 Y:1996 | 08 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,220 | $0 | Not Implemented |
AM0258 # 01 Y:1996 | 01 | 1996 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,385 | $0 | Not Implemented |
AM0258 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,685 | $765 | Implemented |
AM0258 # 03 Y:1996 | 03 | 1996 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,690 | $0 | Implemented |
AM0258 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $1,150 | $600 | Implemented |
AM0258 # 05 Y:1996 | 05 | 1996 | USE SYNTHETIC LUBRICANT | $440 | $0 | Implemented |
AM0258 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $400 | $296 | Implemented |
AM0258 # 07 Y:1996 | 07 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $5,490 | $10,000 | Implemented |
AM0258 # 08 Y:1996 | 08 | 1996 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $540 | $110 | Implemented |
KG0025 # 01 Y:1995 | 01 | 1995 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $28,787 | $7,200 | Implemented |
KG0025 # 02 Y:1995 | 02 | 1995 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $21,682 | $0 | Not Implemented |
KG0025 # 03 Y:1995 | 03 | 1995 | INSULATE BARE EQUIPMENT | $20,807 | $284 | Implemented |
KG0025 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,160 | $6,450 | Implemented |
KG0025 # 05 Y:1995 | 05 | 1995 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,950 | $60 | Not Implemented |
KG0025 # 06 Y:1995 | 06 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,632 | $20 | Implemented |
KG0025 # 07 Y:1995 | 07 | 1995 | INSTALL OCCUPANCY SENSORS | $451 | $325 | Implemented |
AM0239 # 01 Y:1995 | 01 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,240 | $0 | Not Implemented |
AM0239 # 02 Y:1995 | 02 | 1995 | OPTIMIZE PLANT POWER FACTOR | $19,120 | $23,550 | Implemented |
AM0239 # 03 Y:1995 | 03 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,680 | $0 | Implemented |
AM0239 # 04 Y:1995 | 04 | 1995 | INSTALL SKYLIGHTS | $1,180 | $2,550 | Not Implemented |
AM0239 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $920 | $170 | Not Implemented |
AM0239 # 06 Y:1995 | 06 | 1995 | PAY UTILITY BILLS ON TIME | $753 | $0 | Implemented |