Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,727

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0113 # 06 Y:1998 06 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $1,049 $1,235 Implemented
MS0113 # 07 Y:1998 07 1998 BURN WASTE OIL FOR HEAT $1,952 $2,745 Not Implemented
OR0320 # 01 Y:1998 01 1998 OPTIMIZE PLANT POWER FACTOR $25,112 $0 Not Implemented
OR0320 # 02 Y:1998 02 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,076 $0 Not Implemented
OR0320 # 03 Y:1998 03 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,078 $7,300 Implemented
OR0320 # 04 Y:1998 04 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,009 $9,609 Implemented
OR0320 # 05 Y:1998 05 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $857 $0 Not Implemented
OR0320 # 06 Y:1998 06 1998 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $27,785 $0 Implemented
OR0320 # 07 Y:1998 07 1998 INSTALL AUTOMATIC PACKING EQUIPMENT $94,439 $150,000 Not Implemented
OR0320 # 08 Y:1998 08 1998 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $5,087 $6,000 Not Implemented
OR0320 # 09 Y:1998 09 1998 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,387 $0 Not Implemented
OR0320 # 10 Y:1998 10 1998 INSULATE BARE EQUIPMENT $6,161 $217 Not Implemented
KU0494 # 01 Y:1998 01 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $20,790 $8,520 Implemented
KU0494 # 02 Y:1998 02 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,030 $1,400 Implemented
KU0494 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,510 $19,700 Implemented
KU0494 # 04 Y:1998 04 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,960 $2,390 Not Implemented
KU0494 # 05 Y:1998 05 1998 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $1,100 $1,250 Not Implemented
KU0494 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $510 $720 Implemented
KU0494 # 07 Y:1998 07 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $340 $880 Implemented
KU0494 # 08 Y:1998 08 1998 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $4,260 $9,000 Not Implemented
KU0494 # 09 Y:1998 09 1998 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $30,350 $31,830 Implemented
KU0494 # 10 Y:1998 10 1998 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $8,330 $6,280 Not Implemented
MS0110 # 01 Y:1998 01 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $3,125 $0 Implemented
MS0110 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $562 $99 Implemented
MS0110 # 03 Y:1998 03 1998 USE SYNTHETIC LUBRICANT $641 $94 Implemented