Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
145
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1804 # 11 Y:2018 | 11 | 2018 | INSULATE BARE EQUIPMENT | $1,814 | $704 | n/a |
UK1804 # 12 Y:2018 | 12 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $493 | $1,150 | n/a |
UK1804 # 13 Y:2018 | 13 | 2018 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $24,936 | $117,925 | n/a |
UK1804 # 14 Y:2018 | 14 | 2018 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,393 | $1,316 | n/a |
UK1804 # 15 Y:2018 | 15 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $681 | $0 | n/a |
UK1504 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,404 | $93,500 | Not Implemented |
UK1504 # 02 Y:2015 | 02 | 2015 | USE PHOTOCELL CONTROLS | $5,777 | $34,255 | Not Implemented |
UK1504 # 03 Y:2015 | 03 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $453 | $405 | Implemented |
UK1504 # 04 Y:2015 | 04 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,355 | $2,550 | Not Implemented |
UK1504 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,588 | $1,750 | Implemented |
UK1504 # 06 Y:2015 | 06 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,819 | $0 | Implemented |
UK1504 # 07 Y:2015 | 07 | 2015 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $6,448 | $6,381 | Implemented |
UK1504 # 08 Y:2015 | 08 | 2015 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,299 | $2,520 | Not Implemented |
UK1504 # 09 Y:2015 | 09 | 2015 | INSULATE BARE EQUIPMENT | $2,405 | $810 | Implemented |
UK1504 # 10 Y:2015 | 10 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,473 | $0 | Implemented |
UK1504 # 11 Y:2015 | 11 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $9,705 | $17,000 | Not Implemented |
UK1503 # 01 Y:2015 | 01 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $605 | $960 | Implemented |
UK1503 # 02 Y:2015 | 02 | 2015 | USE PHOTOCELL CONTROLS | $3,487 | $4,040 | Implemented |
UK1503 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $945 | $520 | Implemented |
UK1503 # 04 Y:2015 | 04 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $5,138 | $3,760 | Implemented |
UK1503 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,831 | $3,000 | Implemented |
UK1503 # 06 Y:2015 | 06 | 2015 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $16,001 | $5,000 | Implemented |
UK1503 # 07 Y:2015 | 07 | 2015 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,126 | $1,460 | Implemented |
UK1503 # 08 Y:2015 | 08 | 2015 | MINIMIZE WATER USAGE | $556 | $2,470 | Implemented |
UK1503 # 09 Y:2015 | 09 | 2015 | INSULATE BARE EQUIPMENT | $17,159 | $9,380 | Implemented |