Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
226
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0277 # 06 Y:2000 | 06 | 2000 | MODIFY STARTUP/SHUTDOWN TIMES | $1,239 | $120 | Not Implemented |
AS0277 # 05 Y:2000 | 05 | 2000 | ADOPT IN-HOUSE MATERIAL GENERATION | $71,251 | $9,660 | Not Implemented |
AS0277 # 04 Y:2000 | 04 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $864 | $60 | Not Implemented |
AS0277 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,336 | $5,790 | Not Implemented |
AS0277 # 02 Y:2000 | 02 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,074 | $7,709 | Not Implemented |
AS0277 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,580 | $220 | Not Implemented |
AS0273 # 07 Y:2000 | 07 | 2000 | APPLY FOR INVESTMENT INCENTIVES | $137 | $60 | Not Implemented |
AS0273 # 01 Y:2000 | 01 | 2000 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $948 | $920 | Not Implemented |
AS0273 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,057 | $120 | Not Implemented |
AS0273 # 03 Y:2000 | 03 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $157 | $150 | Not Implemented |
AS0273 # 04 Y:2000 | 04 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $470 | $1,000 | Not Implemented |
AS0273 # 06 Y:2000 | 06 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,270 | $120 | Not Implemented |
AS0273 # 08 Y:2000 | 08 | 2000 | EXPAND OPERATIONS INTO UNUSED SPACE | $10,475 | $3,200 | Not Implemented |
AS0273 # 05 Y:2000 | 05 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,780 | $60 | Not Implemented |
AS0272 # 07 Y:2000 | 07 | 2000 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $2,419 | $295 | Implemented |
AS0272 # 06 Y:2000 | 06 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $299 | $440 | Implemented |
AS0272 # 05 Y:2000 | 05 | 2000 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $365 | $150 | Not Implemented |
AS0272 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $405 | $525 | Not Implemented |
AS0272 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $502 | $781 | Implemented |
AS0272 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,392 | $14,863 | Implemented |
AS0272 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $160 | $145 | Implemented |
AS0245 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,495 | $1,856 | Not Implemented |
AS0245 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,105 | $9,802 | Not Implemented |
AS0245 # 03 Y:1999 | 03 | 1999 | MINIMIZE WATER USAGE | $12,932 | $180 | Not Implemented |
AS0240 # 04 Y:1998 | 04 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,086 | $3,800 | Implemented |