IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

140

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0096 # 04 Y:2013 04 2013 INSTALL OCCUPANCY SENSORS $1,997 $545 Implemented
UA0096 # 05 Y:2013 05 2013 INSTALL TIMERS AND/OR THERMOSTATS $3,456 $1,320 Implemented
UA0096 # 02 Y:2013 02 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $817 $996 Implemented
UA0096 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,715 $39,573 Implemented
UA0096 # 01 Y:2013 01 2013 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $13,079 $0 Implemented
UA0096 # 07 Y:2013 07 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $485 $400 Not Implemented
UA0096 # 08 Y:2013 08 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $321 $1,000 Not Implemented
UA0096 # 06 Y:2013 06 2013 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $766 $8 Not Implemented
MS0226 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,417 $205 Implemented
MS0226 # 01 Y:2003 01 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $18,996 $0 Not Implemented
MS0226 # 05 Y:2003 05 2003 INSTALL TIMERS AND/OR THERMOSTATS $886 $591 Not Implemented
MS0226 # 02 Y:2003 02 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,859 $2,372 Implemented
MS0226 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $2,660 $1,669 Not Implemented
MS0185 # 04 Y:2001 04 2001 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $9,552 $3,309 Not Implemented
MS0185 # 01 Y:2001 01 2001 INSULATE BARE EQUIPMENT $1,548 $503 Not Implemented
MS0185 # 05 Y:2001 05 2001 DISCONNECT BALLASTS $571 $160 Not Implemented
MS0185 # 03 Y:2001 03 2001 INSTALL TIMERS AND/OR THERMOSTATS $180 $236 Not Implemented
MS0185 # 06 Y:2001 06 2001 BURN WASTE OIL FOR HEAT $2,078 $4,461 Not Implemented
MS0185 # 07 Y:2001 07 2001 $159 $50 Not Implemented
MS0185 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $208 $215 Not Implemented
MS0184 # 04 Y:2001 04 2001 INSTALL TIMERS AND/OR THERMOSTATS $702 $875 Not Implemented
MS0184 # 09 Y:2001 09 2001 RECOVER METALS FROM CASTING SAND $9,304 $32 Not Implemented
MS0184 # 02 Y:2001 02 2001 INSTALL TIMERS AND/OR THERMOSTATS $571 $375 Not Implemented
MS0184 # 07 Y:2001 07 2001 USE SYNTHETIC LUBRICANT $44 $17 Not Implemented
MS0184 # 01 Y:2001 01 2001 INSULATE BARE EQUIPMENT $3,051 $348 Not Implemented