Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
339
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0275 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,219 | $1,450 | Not Implemented |
IA0275 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $960 | $147 | Implemented |
IA0275 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,724 | $10,962 | Not Implemented |
IA0275 # 05 Y:2001 | 05 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,769 | $700 | Implemented |
IA0275 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,919 | $0 | Implemented |
IA0275 # 07 Y:2001 | 07 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,067 | $0 | Implemented |
IA0275 # 08 Y:2001 | 08 | 2001 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $722 | $496 | Implemented |
IA0275 # 09 Y:2001 | 09 | 2001 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $21 | $100 | Not Implemented |
IA0275 # 10 Y:2001 | 10 | 2001 | $57,330 | $21,000 | n/a | |
SF0221 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $1,099 | $840 | Not Implemented |
SF0221 # 04 Y:2001 | 04 | 2001 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,217 | $495 | Not Implemented |
SF0221 # 03 Y:2001 | 03 | 2001 | UPGRADE CONTROLS ON COMPRESSORS | $2,046 | $344 | Implemented |
SF0221 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,977 | $480 | Implemented |
SF0221 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $185 | $0 | Implemented |
SF0221 # 06 Y:2001 | 06 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,141 | $7,697 | Not Implemented |
SF0221 # 07 Y:2001 | 07 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,570 | $2,262 | Not Implemented |
SF0221 # 08 Y:2001 | 08 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,259 | $1,259 | Implemented |
SF0221 # 09 Y:2001 | 09 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $53,204 | $139,820 | Not Implemented |
SF0221 # 10 Y:2001 | 10 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $584 | $80 | Implemented |
TA0011 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $730 | $210 | Implemented |
TA0011 # 01 Y:2001 | 01 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,600 | $0 | Implemented |
TA0011 # 02 Y:2001 | 02 | 2001 | INSULATE BARE EQUIPMENT | $2,340 | $360 | Implemented |
TA0011 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,645 | $400 | Implemented |
TA0011 # 05 Y:2001 | 05 | 2001 | USE SYNTHETIC LUBRICANT | $715 | $0 | Not Implemented |
UD0628 # 07 Y:2001 | 07 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,858 | $0 | Implemented |