Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

105

matching recommendations
Reset
SIC 32 Stone, Clay, And Glass Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0561 # 06 Y:1995 06 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $45,730 $201,600 Implemented
GT0547 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,000 $21,180 Implemented
GT0547 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,170 $400 Implemented
GT0547 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $390 $300 Implemented
GT0547 # 06 Y:1995 06 1995 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $7,980 $13,000 Implemented
GT0468 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,495 $84,190 Implemented
GT0468 # 02 Y:1992 02 1992 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $7,368 $3,500 Implemented
GT0468 # 03 Y:1992 03 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $17,240 $0 Implemented
GT0461 # 01 Y:1992 01 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,414 $300 Implemented
GT0461 # 02 Y:1992 02 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,427 $10,500 Implemented
GT0461 # 03 Y:1992 03 1992 REPAIR AND ELIMINATE STEAM LEAKS $5,200 $1,000 Implemented
GT0461 # 04 Y:1992 04 1992 INSULATE BARE EQUIPMENT $13,398 $7,605 Implemented
GT0461 # 05 Y:1992 05 1992 USE MINIMUM STEAM OPERATING PRESSURE $499 $0 Implemented
GT0461 # 06 Y:1992 06 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,164 $2,200 Implemented
GT0461 # 07 Y:1992 07 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,618 $78,930 Implemented
GT0461 # 08 Y:1992 08 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,010 $0 Implemented
GT0461 # 09 Y:1992 09 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,673 $3,500 Implemented
GT0439 # 01 Y:1991 01 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $500 $0 Implemented
GT0439 # 02 Y:1991 02 1991 INCREASE AMOUNT OF CONDENSATE RETURNED $960 $0 Implemented
GT0439 # 03 Y:1991 03 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $158 $289 Implemented
GT0439 # 04 Y:1991 04 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $37,560 $0 Implemented
GT0439 # 05 Y:1991 05 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $183 $0 Implemented
GT0439 # 06 Y:1991 06 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,110 $3,441 Implemented
GT0439 # 07 Y:1991 07 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,900 $4,800 Implemented
GT0439 # 08 Y:1991 08 1991 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,550 $500 Implemented