Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
188
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0185 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,808 | $4,950 | Not Implemented |
NC0185 # 05 Y:2000 | 05 | 2000 | USE OPTIMUM THICKNESS INSULATION | $4,274 | $1,200 | Implemented |
NC0185 # 06 Y:2000 | 06 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,584 | $50 | Implemented |
NC0185 # 07 Y:2000 | 07 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $112 | $90 | Not Implemented |
NC0185 # 08 Y:2000 | 08 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,750 | $1,000 | Implemented |
NC0185 # 09 Y:2000 | 09 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $143,125 | $27,000 | Not Implemented |
NC0162 # 01 Y:1999 | 01 | 1999 | IMPROVE COMBUSTION CONTROL CAPABILITY | $9,405 | $15,000 | Not Implemented |
NC0162 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,501 | $20,000 | Not Implemented |
NC0162 # 03 Y:1999 | 03 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $41,911 | $10,500 | Not Implemented |
NC0162 # 04 Y:1999 | 04 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $7,571 | $9,450 | Not Implemented |
NC0162 # 05 Y:1999 | 05 | 1999 | METER WASTE WATER | $2,279 | $1,500 | Not Implemented |
NC0162 # 06 Y:1999 | 06 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,019 | $1,050 | Not Implemented |
NC0162 # 07 Y:1999 | 07 | 1999 | IMPROVE HANDLING PRACTICES | $1,609 | $1,500 | Not Implemented |
NC0162 # 08 Y:1999 | 08 | 1999 | MOVE PRODUCT USING MECHANICAL MEANS | $1,509 | $5,200 | Not Implemented |
NC0149 # 01 Y:1998 | 01 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $79,194 | $118,650 | Not Implemented |
NC0149 # 02 Y:1998 | 02 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,438 | $100 | Implemented |
NC0149 # 03 Y:1998 | 03 | 1998 | PURCHASE APPROPRIATELY SIZED MATERIAL | $6,400 | $1,000 | Implemented |
NC0149 # 04 Y:1998 | 04 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $938 | $200 | Implemented |
NC0149 # 05 Y:1998 | 05 | 1998 | RECYCLE CLEANING SOLVENT AND REUSE | $1,472 | $100 | Implemented |
NC0149 # 06 Y:1998 | 06 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $4,320 | $800 | Implemented |
NC0148 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,914 | $10,000 | Not Implemented |
NC0148 # 02 Y:1998 | 02 | 1998 | REDUCE FLUID FLOW RATES | $304 | $550 | Implemented |
NC0148 # 03 Y:1998 | 03 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $7,677 | $10,000 | Implemented |
NC0148 # 04 Y:1998 | 04 | 1998 | INSTALL EQUIPMENT TO MOVE PRODUCT | $63,429 | $80,000 | Implemented |
NC0127 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,930 | $1,880 | Implemented |