Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
315
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0478 # 11 Y:2013 | 11 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,342 | $4,080 | Not Implemented |
WV0418 # 01 Y:2010 | 01 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $138,747 | $25,000 | Not Implemented |
WV0418 # 02 Y:2010 | 02 | 2010 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $81,321 | $88,248 | Not Implemented |
WV0418 # 03 Y:2010 | 03 | 2010 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $69,991 | $24,464 | Not Implemented |
WV0418 # 04 Y:2010 | 04 | 2010 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $44,522 | $17,594 | Not Implemented |
WV0418 # 05 Y:2010 | 05 | 2010 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $35,021 | $47,775 | Not Implemented |
WV0418 # 06 Y:2010 | 06 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $33,207 | $16,040 | Not Implemented |
WV0418 # 07 Y:2010 | 07 | 2010 | INSULATE BARE EQUIPMENT | $22,652 | $9,549 | Implemented |
WV0418 # 08 Y:2010 | 08 | 2010 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $17,763 | $2,000 | Implemented |
WV0418 # 09 Y:2010 | 09 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $15,821 | $1,715 | Implemented |
WV0418 # 10 Y:2010 | 10 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,568 | $19,614 | Implemented |
WV0418 # 11 Y:2010 | 11 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,872 | $35,956 | Implemented |
WV0418 # 12 Y:2010 | 12 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,456 | $5,095 | Implemented |
WV0418 # 13 Y:2010 | 13 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,837 | $3,870 | Not Implemented |
WV0418 # 14 Y:2010 | 14 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,456 | $621 | Implemented |
WV0418 # 15 Y:2010 | 15 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,931 | $0 | Implemented |
WV0418 # 16 Y:2010 | 16 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $4,116 | $0 | Implemented |
WV0418 # 17 Y:2010 | 17 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $866 | $2,717 | Implemented |
WV0418 # 18 Y:2010 | 18 | 2010 | IMPROVE LUBRICATION PRACTICES | $370 | $466 | Implemented |
WV0404 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $795,452 | $529,924 | Not Implemented |
WV0404 # 02 Y:2010 | 02 | 2010 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $464,158 | $180,000 | Not Implemented |
WV0404 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $151,596 | $109,360 | Not Implemented |
WV0404 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $45,647 | $65,720 | Implemented |
WV0404 # 05 Y:2010 | 05 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $31,815 | $12,720 | Implemented |
WV0404 # 06 Y:2010 | 06 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,235 | $6,000 | Implemented |