Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
330
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0152 # 07 Y:1998 | 07 | 1998 | BURN A LESS EXPENSIVE GRADE OF FUEL | $9,550 | $8,400 | Not Implemented |
WV0152 # 08 Y:1998 | 08 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $960 | $50 | Implemented |
WV0152 # 09 Y:1998 | 09 | 1998 | RECYCLE FLUORESCENT LAMPS | $400 | $45 | Not Implemented |
WV0152 # 10 Y:1998 | 10 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $24,414 | $3,000 | Implemented |
HO0185 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $229 | $808 | Implemented |
HO0185 # 02 Y:1998 | 02 | 1998 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $3,970 | $20,000 | Not Implemented |
HO0185 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $2,751 | $3,981 | Implemented |
HO0185 # 04 Y:1998 | 04 | 1998 | COMBINE UTILITY METERS | $5,982 | $3,000 | Not Implemented |
HO0185 # 05 Y:1998 | 05 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $15,606 | $2,500 | Not Implemented |
WV0144 # 01 Y:1998 | 01 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $588 | $0 | Implemented |
WV0144 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $8,584 | $1,007 | Implemented |
WV0144 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,478 | $140 | Not Implemented |
WV0144 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,816 | $560 | Implemented |
WV0144 # 05 Y:1998 | 05 | 1998 | INSULATE BARE EQUIPMENT | $5,809 | $263 | Not Implemented |
WV0144 # 06 Y:1998 | 06 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,804 | $2,000 | Not Implemented |
WV0144 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,565 | $3,310 | Implemented |
WV0144 # 08 Y:1998 | 08 | 1998 | USE SYNTHETIC LUBRICANT | $2,801 | $390 | Implemented |
WV0144 # 09 Y:1998 | 09 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $35,092 | $0 | Not Implemented |
WV0144 # 10 Y:1998 | 10 | 1998 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $122 | $0 | Not Implemented |
WV0144 # 11 Y:1998 | 11 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,403 | $11,000 | Not Implemented |
WV0144 # 12 Y:1998 | 12 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $23,400 | $8,050 | Not Implemented |
WV0144 # 13 Y:1998 | 13 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $6,700 | $60 | Implemented |
WV0144 # 14 Y:1998 | 14 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $300 | $60 | Implemented |
WV0144 # 15 Y:1998 | 15 | 1998 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $83,200 | $1,673 | Implemented |
WV0143 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $276 | $281 | Implemented |