Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
16
matching recommendationsSIC | 322 | Glass And Glassware, Pressed Or Blown |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0518 # 01 Y:2018 | 01 | 2018 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $13,874 | $3,023 | Not Implemented |
SF0518 # 02 Y:2018 | 02 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,220 | $4,857 | Not Implemented |
SF0518 # 03 Y:2018 | 03 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,611 | $15,000 | Not Implemented |
SF0518 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,777 | $2,300 | Not Implemented |
SF0518 # 05 Y:2018 | 05 | 2018 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $2,098 | $6,325 | Not Implemented |
SF0518 # 06 Y:2018 | 06 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $6,223 | $45,702 | Not Implemented |
MZ0250 # 01 Y:2018 | 01 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,351 | $5,600 | Implemented |
MZ0250 # 02 Y:2018 | 02 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $27,014 | $65,000 | Not Implemented |
MZ0250 # 03 Y:2018 | 03 | 2018 | INSTALL OCCUPANCY SENSORS | $1,786 | $280 | Implemented |
MZ0250 # 04 Y:2018 | 04 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $20,697 | $0 | Implemented |
OK0981 # 01 Y:2018 | 01 | 2018 | UPGRADE CONTROLS ON COMPRESSORS | $124,716 | $75,000 | Implemented |
OK0981 # 02 Y:2018 | 02 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,815 | $0 | Not Implemented |
OK0981 # 03 Y:2018 | 03 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $16,309 | $4,937 | Not Implemented |
OK0981 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,343 | $69,050 | Not Implemented |
OK0981 # 05 Y:2018 | 05 | 2018 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $353,111 | $2,500,000 | Not Implemented |
OK0981 # 06 Y:2018 | 06 | 2018 | OPTIMIZE PLANT POWER FACTOR | $11,423 | $50,570 | Not Implemented |