Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
383
matching recommendationsSIC | 3231 | Products Of Purchased Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0365 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $779 | $19 | Implemented |
IA0365 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,995 | $3,000 | Implemented |
IA0365 # 05 Y:2005 | 05 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $628 | $1,600 | Implemented |
IA0365 # 06 Y:2005 | 06 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $1,000,000 | $152,672 | Implemented |
IA0365 # 08 Y:2005 | 08 | 2005 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $21,000 | $7,216 | Implemented |
OR0482 # 04 Y:2005 | 04 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,526 | $0 | Implemented |
CO0558 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,990 | $350 | Implemented |
CO0558 # 02 Y:2004 | 02 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,700 | $2,720 | Implemented |
CO0558 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,020 | $6,030 | Implemented |
CO0558 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $234 | $588 | Implemented |
CO0558 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,660 | $7,410 | Implemented |
MI0088 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $28,772 | $2,300 | Implemented |
MI0088 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $-1,117 | $750 | Implemented |
MI0088 # 04 Y:2004 | 04 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $22,760 | $40,140 | Implemented |
MI0088 # 05 Y:2004 | 05 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $427,935 | $0 | Implemented |
MI0088 # 08 Y:2004 | 08 | 2004 | PAY BILLS ON TIME TO AVOID LATE FEES | $770 | $0 | Implemented |
LM0077 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $117 | $0 | Implemented |
LM0077 # 03 Y:2004 | 03 | 2004 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $91 | $100 | Implemented |
LM0077 # 05 Y:2004 | 05 | 2004 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $812 | $0 | Implemented |
LE0161 # 02 Y:2003 | 02 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,365 | $3,000 | Implemented |
LE0161 # 04 Y:2003 | 04 | 2003 | INSULATE BARE EQUIPMENT | $17,796 | $6,000 | Implemented |
LE0161 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,814 | $0 | Implemented |
WI0433 # 01 Y:2002 | 01 | 2002 | CONVERT FROM BATCH OPERATION TO CONTINUOUS PROCESSING | $14,150 | $13,000 | Implemented |
WI0433 # 02 Y:2002 | 02 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,467 | $20,000 | Implemented |
WI0433 # 04 Y:2002 | 04 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,251 | $1,100 | Implemented |