Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
740
matching recommendationsSIC | 3231 | Products Of Purchased Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0435 # 07 Y:2008 | 07 | 2008 | INSTALL OCCUPANCY SENSORS | $552 | $1,309 | Implemented |
IA0435 # 08 Y:2008 | 08 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,096 | $317 | Not Implemented |
IA0435 # 09 Y:2008 | 09 | 2008 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,838 | $15 | Implemented |
MI0172 # 01 Y:2008 | 01 | 2008 | RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION | $126,000 | $66,640 | Not Implemented |
MI0172 # 02 Y:2008 | 02 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $86,926 | $83,640 | Implemented |
MI0172 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,860 | $8,778 | Implemented |
MI0172 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,695 | $1,210 | Implemented |
MI0172 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $343 | $24 | Implemented |
MI0172 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,883 | $1,210 | Implemented |
MI0172 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,251 | $24 | Implemented |
MI0172 # 08 Y:2008 | 08 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $728 | $1,200 | Implemented |
CO0615 # 01 Y:2008 | 01 | 2008 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,560 | $12,000 | Not Implemented |
CO0615 # 02 Y:2008 | 02 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,490 | $1,000 | Implemented |
CO0615 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,960 | $1,500 | Implemented |
CO0615 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,280 | $13,730 | Not Implemented |
CO0615 # 05 Y:2008 | 05 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,930 | $11,000 | Not Implemented |
CO0611 # 01 Y:2008 | 01 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,560 | $23,950 | Not Implemented |
CO0611 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,550 | $200 | Implemented |
CO0611 # 03 Y:2008 | 03 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $500 | $1,755 | Implemented |
CO0611 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,810 | $33,480 | Not Implemented |
CO0611 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,360 | $20,290 | Implemented |
CO0611 # 06 Y:2008 | 06 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,770 | $11,000 | Not Implemented |
NC0374 # 01 Y:2008 | 01 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $32,923 | $63,000 | Implemented |
NC0374 # 02 Y:2008 | 02 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,372 | $18,000 | Implemented |
NC0374 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,977 | $100 | Implemented |