Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsSIC | 325 | Structural Clay Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0097 # 02 Y:1997 | 02 | 1997 | OPTIMIZE PLANT POWER FACTOR | $4,746 | $1,326 | Implemented |
MS0097 # 03 Y:1997 | 03 | 1997 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $828 | $482 | Not Implemented |
MS0097 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,896 | $8,648 | Implemented |
MS0097 # 05 Y:1997 | 05 | 1997 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $5,931 | $1,158 | Implemented |
MS0097 # 06 Y:1997 | 06 | 1997 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $26,125 | $32,289 | Implemented |
MS0097 # 01 Y:1997 | 01 | 1997 | USE OPTIMUM THICKNESS INSULATION | $78,996 | $81,321 | Not Implemented |
NC0127 # 08 Y:1997 | 08 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $11,985 | $2,850 | Not Implemented |
NC0127 # 07 Y:1997 | 07 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $136,000 | $100,000 | Not Implemented |
NC0127 # 06 Y:1997 | 06 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $109,730 | $100,000 | Not Implemented |
NC0127 # 05 Y:1997 | 05 | 1997 | REDESIGN PROCESS | $519 | $50 | Not Implemented |
NC0127 # 04 Y:1997 | 04 | 1997 | USE OPTIMUM THICKNESS INSULATION | $2,940 | $17,640 | Not Implemented |
NC0127 # 03 Y:1997 | 03 | 1997 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,143 | $2,915 | Not Implemented |
NC0127 # 02 Y:1997 | 02 | 1997 | INSTALL OCCUPANCY SENSORS | $130 | $125 | Not Implemented |
NC0127 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,930 | $1,880 | Implemented |
MO0202 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,936 | $1,342 | Implemented |
MO0202 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,601 | $4,624 | Implemented |
MO0202 # 04 Y:1997 | 04 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $4,800 | $12,500 | Implemented |
MO0202 # 08 Y:1997 | 08 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $227 | $40 | Not Implemented |
MO0202 # 10 Y:1997 | 10 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $7,626 | $200 | Implemented |
MO0202 # 09 Y:1997 | 09 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $120 | $45 | Not Implemented |
MO0202 # 07 Y:1997 | 07 | 1997 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,874 | $3,137 | Implemented |
MO0202 # 03 Y:1997 | 03 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $11,610 | $3,500 | Implemented |
MO0202 # 11 Y:1997 | 11 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $984 | $2,500 | Not Implemented |
MO0202 # 02 Y:1997 | 02 | 1997 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $14,720 | $20,000 | Implemented |
MO0202 # 01 Y:1997 | 01 | 1997 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $34,950 | $25,000 | Implemented |