Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
129
matching recommendationsSIC | 3251 | Brick And Structural Clay Tile |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0314 # 02 Y:2005 | 02 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $848 | $1,393 | Implemented |
NC0314 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,259 | $379 | Implemented |
NC0314 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,022 | $100 | Implemented |
NC0314 # 05 Y:2005 | 05 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,252 | $2,552 | Implemented |
NC0314 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,356 | $660 | Implemented |
SD0351 # 02 Y:2004 | 02 | 2004 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $80,766 | $255,442 | Implemented |
SD0351 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $34,754 | $39,050 | Implemented |
SD0351 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,248 | $14,785 | Implemented |
SD0351 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,257 | $350 | Implemented |
SD0351 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $663 | $0 | Implemented |
SD0351 # 07 Y:2004 | 07 | 2004 | PAY UTILITY BILLS ON TIME | $1,391 | $0 | Implemented |
LE0139 # 01 Y:2002 | 01 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $97,133 | $238,263 | Implemented |
LE0139 # 03 Y:2002 | 03 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,359 | $0 | Implemented |
WV0245 # 01 Y:2002 | 01 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,684 | $0 | Implemented |
WV0245 # 02 Y:2002 | 02 | 2002 | INSULATE BARE EQUIPMENT | $348 | $151 | Implemented |
WV0245 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $945 | $0 | Implemented |
WV0245 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $414 | $100 | Implemented |
WV0245 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $6,015 | $230 | Implemented |
WV0245 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,109 | $138 | Implemented |
WV0245 # 08 Y:2002 | 08 | 2002 | USE PHOTOCELL CONTROLS | $579 | $300 | Implemented |
WV0245 # 10 Y:2002 | 10 | 2002 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $3,800 | $690 | Implemented |
MA0509 # 02 Y:2002 | 02 | 2002 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $18,790 | $45,905 | Implemented |
MA0509 # 03 Y:2002 | 03 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,396 | $0 | Implemented |
MA0509 # 04 Y:2002 | 04 | 2002 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $3,396 | $4,200 | Implemented |
MA0509 # 05 Y:2002 | 05 | 2002 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $2,790 | $1,200 | Implemented |