Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 3259 | Structural Clay Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0325 # 02 Y:2010 | 02 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,692 | $30 | Implemented |
LL0325 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,019 | $1,265 | Implemented |
LL0325 # 01 Y:2010 | 01 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $40,139 | $3,000 | Implemented |
UD0636 # 01 Y:2002 | 01 | 2002 | INCREASE USE OF AUTOMATION | $62,400 | $0 | Implemented |
UD0636 # 10 Y:2002 | 10 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $736 | $300 | Implemented |
UD0636 # 09 Y:2002 | 09 | 2002 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $1,223 | $0 | Implemented |
UD0636 # 08 Y:2002 | 08 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,335 | $420 | Implemented |
UD0636 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,509 | $2,880 | Implemented |
UD0636 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,668 | $1,185 | Implemented |
UD0636 # 05 Y:2002 | 05 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,247 | $500 | Implemented |
UD0636 # 04 Y:2002 | 04 | 2002 | OPTIMIZE PLANT POWER FACTOR | $4,987 | $3,750 | Implemented |
UD0636 # 03 Y:2002 | 03 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $20,230 | $25,000 | Implemented |
UD0636 # 02 Y:2002 | 02 | 2002 | INSULATE BARE EQUIPMENT | $20,587 | $7,200 | Implemented |
UL0232 # 03 Y:1999 | 03 | 1999 | RECOVER AND REUSE COOLING WATER | $56,903 | $5,370 | Implemented |
TN0628 # 09 Y:1998 | 09 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,950 | $0 | Implemented |
TN0628 # 08 Y:1998 | 08 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,560 | $2,170 | Implemented |
TN0628 # 06 Y:1998 | 06 | 1998 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $3,690 | $10,500 | Implemented |
TN0628 # 05 Y:1998 | 05 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,815 | $5,600 | Implemented |
TN0628 # 04 Y:1998 | 04 | 1998 | RECOVER AND REUSE WASTE MATERIAL | $5,910 | $16,880 | Implemented |
TN0628 # 02 Y:1998 | 02 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $24,400 | $0 | Implemented |
WV0108 # 04 Y:1997 | 04 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,631 | $1,200 | Implemented |
WV0108 # 09 Y:1997 | 09 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $54,000 | $0 | Implemented |
WV0108 # 11 Y:1997 | 11 | 1997 | REVISE RAW MATERIAL SPECS | $36,895 | $4,293 | Implemented |
WV0108 # 08 Y:1997 | 08 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $6,000 | $200 | Implemented |
WV0108 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,294 | $393 | Implemented |