Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
397
matching recommendationsSIC | 326 | Pottery And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0484 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,039 | $1,124 | Not Implemented |
NC0484 # 05 Y:2013 | 05 | 2013 | USE PHOTOCELL CONTROLS | $2,065 | $250 | Implemented |
NC0484 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $56,670 | $60,000 | Not Implemented |
NC0484 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,306 | $100 | Implemented |
WV0441 # 15 Y:2012 | 15 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,137 | $1,063 | Implemented |
WV0441 # 14 Y:2012 | 14 | 2012 | IMPROVE LUBRICATION PRACTICES | $2,709 | $3,400 | Not Implemented |
WV0441 # 13 Y:2012 | 13 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,782 | $0 | Implemented |
WV0441 # 12 Y:2012 | 12 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,825 | $12,850 | Not Implemented |
WV0441 # 11 Y:2012 | 11 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,115 | $3,000 | Not Implemented |
WV0441 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,022 | $9,275 | Implemented |
WV0441 # 09 Y:2012 | 09 | 2012 | OPTIMIZE PLANT POWER FACTOR | $10,618 | $46,340 | Not Implemented |
WV0441 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,024 | $37,887 | Implemented |
WV0441 # 07 Y:2012 | 07 | 2012 | INSULATE BARE EQUIPMENT | $20,023 | $6,777 | Not Implemented |
WV0441 # 06 Y:2012 | 06 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $38,793 | $10,750 | Implemented |
WV0441 # 05 Y:2012 | 05 | 2012 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $49,557 | $11,000 | Implemented |
WV0441 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $64,675 | $91,200 | Implemented |
WV0441 # 03 Y:2012 | 03 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $73,647 | $33,378 | Implemented |
WV0441 # 02 Y:2012 | 02 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $78,225 | $74,340 | Not Implemented |
WV0441 # 01 Y:2012 | 01 | 2012 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $200,857 | $610,000 | Not Implemented |
NC0420 # 03 Y:2011 | 03 | 2011 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $67,800 | $304,000 | Not Implemented |
NC0420 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,026 | $62,095 | Implemented |
NC0420 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,618 | $130,787 | Implemented |
NC0420 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,604 | $100 | Implemented |
NC0420 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $23,785 | $0 | Implemented |
NC0420 # 06 Y:2011 | 06 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,434 | $55,000 | Implemented |