Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

122

matching recommendations
Reset
SIC 3264 Porcelain Electrical Supplies
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0292 # 10 Y:2010 10 2010 MOVE BOILER TO MORE EFFICIENT LOCATION $6,648 $60,575 Not Implemented
SU0292 # 02 Y:2010 02 2010 REPAIR AND ELIMINATE STEAM LEAKS $4,309 $46 Implemented
SU0292 # 01 Y:2010 01 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $22,577 $0 Not Implemented
SU0292 # 06 Y:2010 06 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35,377 $81,156 Not Implemented
SU0292 # 09 Y:2010 09 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,849 $24,883 Not Implemented
SU0292 # 07 Y:2010 07 2010 RECOVER WASTE HEAT FROM EQUIPMENT $57,316 $175,000 Not Implemented
SU0229 # 02 Y:2006 02 2006 $12,392 $0 Implemented
SU0229 # 01 Y:2006 01 2006 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $14,635 $0 Not Implemented
SU0229 # 08 Y:2006 08 2006 KEEP BOILER TUBES CLEAN $5,210 $1,534 Implemented
SU0229 # 06 Y:2006 06 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,224 $0 Implemented
SU0229 # 09 Y:2006 09 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,794 $563 Not Implemented
SU0229 # 11 Y:2006 11 2006 INSTALL OCCUPANCY SENSORS $145 $222 Not Implemented
SU0229 # 04 Y:2006 04 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,547 $0 Not Implemented
SU0229 # 05 Y:2006 05 2006 USE SYNTHETIC LUBRICANT $3,930 $0 Implemented
SU0229 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,878 $0 Implemented
SU0229 # 14 Y:2006 14 2006 INSULATE BARE EQUIPMENT $781 $2,198 Not Implemented
SU0229 # 07 Y:2006 07 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,893 $630 Implemented
SU0229 # 10 Y:2006 10 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $238 $313 Not Implemented
SU0229 # 12 Y:2006 12 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,544 $26,000 Not Implemented
SU0229 # 13 Y:2006 13 2006 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $372 $845 Not Implemented
SF0277 # 09 Y:2004 09 2004 INSTALL OCCUPANCY SENSORS $1,907 $3,072 Not Implemented
SF0277 # 10 Y:2004 10 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,365 $41,948 Not Implemented
SF0277 # 08 Y:2004 08 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,600 $13,520 Implemented
SF0277 # 04 Y:2004 04 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $954 $240 Not Implemented
SF0277 # 05 Y:2004 05 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $784 $240 Implemented