Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
736
matching recommendationsSIC | 3272 | Concrete Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0391 # 10 Y:2009 | 10 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $374 | $300 | Implemented |
LL0311 # 01 Y:2009 | 01 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $17,835 | $9,450 | Not Implemented |
LL0311 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,239 | $680 | Implemented |
LL0311 # 03 Y:2009 | 03 | 2009 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,635 | $600 | Implemented |
LL0311 # 04 Y:2009 | 04 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $522 | $1,650 | Not Implemented |
LL0311 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $147 | $760 | Not Implemented |
LL0311 # 06 Y:2009 | 06 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $94 | $210 | Implemented |
NC0376 # 01 Y:2008 | 01 | 2008 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $12,423 | $15,000 | Not Implemented |
NC0376 # 02 Y:2008 | 02 | 2008 | ADJUST BURNERS FOR EFFICIENT OPERATION | $44,894 | $1,000 | Implemented |
NC0376 # 03 Y:2008 | 03 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $32,459 | $75,000 | Implemented |
NC0376 # 04 Y:2008 | 04 | 2008 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $42,026 | $7,815 | Not Implemented |
NC0376 # 05 Y:2008 | 05 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $21,163 | $50 | Not Implemented |
NC0376 # 06 Y:2008 | 06 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,635 | $3,500 | Not Implemented |
NC0376 # 07 Y:2008 | 07 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $400 | $100 | Implemented |
NC0376 # 08 Y:2008 | 08 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $4,903 | $7,820 | Implemented |
NC0376 # 09 Y:2008 | 09 | 2008 | USE PHOTOCELL CONTROLS | $2,567 | $1,900 | Implemented |
NC0376 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $229 | $507 | Not Implemented |
MI0161 # 01 Y:2008 | 01 | 2008 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $32,580 | $89,078 | Implemented |
MI0161 # 02 Y:2008 | 02 | 2008 | INCREASE EFFICIENCY OF TRUCKS | $27,036 | $41,580 | Not Implemented |
MI0161 # 03 Y:2008 | 03 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,253 | $1,800 | Not Implemented |
MI0161 # 04 Y:2008 | 04 | 2008 | INCREASE EFFICIENCY OF TRUCKS | $50,304 | $150,300 | Not Implemented |
MI0161 # 05 Y:2008 | 05 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,779 | $720 | Implemented |
MI0161 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,042 | $1,032 | Implemented |
MI0161 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $295 | $24 | Implemented |
GT0837 # 01 Y:2007 | 01 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,990 | $0 | Implemented |