IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

279

matching recommendations
Reset
SIC 3275 Gypsum Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0252 # 01 Y:1998 01 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $67,656 $52,600 Implemented
ME0252 # 02 Y:1998 02 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $15,186 $28,000 Implemented
ME0252 # 03 Y:1998 03 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,928 $2,675 Implemented
ME0252 # 04 Y:1998 04 1998 INSULATE BARE EQUIPMENT $4,866 $6,900 Not Implemented
ME0252 # 05 Y:1998 05 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,171 $1,923 Implemented
ME0252 # 06 Y:1998 06 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,309 $1,457 Implemented
ME0252 # 07 Y:1998 07 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,213 $1,405 Implemented
ME0252 # 08 Y:1998 08 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $466 $225 Implemented
ME0252 # 09 Y:1998 09 1998 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $233 $375 Implemented
ME0252 # 10 Y:1998 10 1998 PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW $89,700 $11,750 Implemented
ME0252 # 11 Y:1998 11 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $480 $0 Not Implemented
AR0144 # 01 Y:1998 01 1998 OPTIMIZE PLANT POWER FACTOR $9,562 $14,895 Not Implemented
AR0144 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,907 $1,060 Not Implemented
AR0144 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $530 $333 Implemented
AR0144 # 04 Y:1998 04 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,876 $0 Not Implemented
AR0144 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,575 $160 Implemented
AR0144 # 06 Y:1998 06 1998 INSULATE BARE EQUIPMENT $7,588 $10,500 Not Implemented
AR0144 # 07 Y:1998 07 1998 METER WASTE WATER $6,423 $500 Not Implemented
AR0144 # 08 Y:1998 08 1998 PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW $23,958 $0 Not Implemented
AR0144 # 09 Y:1998 09 1998 AUTOMATE PAYROLL SYSTEM $217,800 $85,000 Not Implemented
ND0247 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $182 $340 Not Implemented
ND0247 # 02 Y:1996 02 1996 INSTALL OCCUPANCY SENSORS $238 $400 Implemented
ND0247 # 03 Y:1996 03 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $140 $840 Not Implemented
ND0247 # 04 Y:1996 04 1996 USE PHOTOCELL CONTROLS $780 $600 Not Implemented
ND0247 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $297 $243 Implemented