IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

28

matching recommendations
Reset
SIC 3275 Gypsum Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0666 # 10 Y:1999 10 1999 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,800 $0 Implemented
GT0666 # 09 Y:1999 09 1999 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $52,500 $45,000 Not Implemented
GT0666 # 08 Y:1999 08 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $38,797 $151,526 Implemented
GT0666 # 07 Y:1999 07 1999 INSULATE BARE EQUIPMENT $7,967 $8,398 Not Implemented
GT0666 # 06 Y:1999 06 1999 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,354 $3,900 Not Implemented
GT0666 # 05 Y:1999 05 1999 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $30,735 $8,017 Not Implemented
GT0666 # 04 Y:1999 04 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,598 $2,500 Implemented
GT0666 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,440 $450 Implemented
GT0666 # 02 Y:1999 02 1999 ADJUST BURNERS FOR EFFICIENT OPERATION $366,782 $180,000 Implemented
GT0666 # 01 Y:1999 01 1999 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $30,744 $35,000 Implemented
AM0344 # 04 Y:1999 04 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $21,800 $0 Implemented
AM0344 # 07 Y:1999 07 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $205 $250 Implemented
AM0344 # 06 Y:1999 06 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $610 $0 Implemented
AM0344 # 05 Y:1999 05 1999 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,150 $140 Implemented
AM0344 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $27,000 $850 Not Implemented
AM0344 # 02 Y:1999 02 1999 RECOVER AND REUSE WASTE MATERIAL $93,150 $110,000 Not Implemented
AM0344 # 01 Y:1999 01 1999 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $481,000 $1,207,000 Not Implemented
AM0341 # 01 Y:1999 01 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,300 $500 Implemented
AM0341 # 11 Y:1999 11 1999 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $150 $0 Not Implemented
AM0341 # 10 Y:1999 10 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $250 $0 Not Implemented
AM0341 # 09 Y:1999 09 1999 USE SYNTHETIC LUBRICANT $415 $0 Implemented
AM0341 # 08 Y:1999 08 1999 INSULATE BARE EQUIPMENT $540 $905 Implemented
AM0341 # 07 Y:1999 07 1999 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $650 $0 Not Implemented
AM0341 # 06 Y:1999 06 1999 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $720 $0 Not Implemented
AM0341 # 05 Y:1999 05 1999 USE SYNTHETIC LUBRICANT $3,380 $0 Implemented