Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,537
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0073 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $801 | $400 | Implemented |
WI0073 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $880 | $1,000 | Implemented |
WI0073 # 07 Y:1989 | 07 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $594 | $800 | Implemented |
WI0073 # 09 Y:1989 | 09 | 1989 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $236 | $0 | Implemented |
TN0386 # 01 Y:1989 | 01 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,995 | $9,500 | Implemented |
TN0386 # 03 Y:1989 | 03 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,664 | $0 | Implemented |
TN0386 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,407 | $3,860 | Implemented |
TN0386 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $659 | $500 | Implemented |
CO0163 # 02 Y:1989 | 02 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $480 | $600 | Implemented |
CO0163 # 03 Y:1989 | 03 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $900 | $500 | Implemented |
CO0163 # 05 Y:1989 | 05 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $570 | $400 | Implemented |
CO0163 # 06 Y:1989 | 06 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $340 | $130 | Implemented |
MA0154 # 01 Y:1989 | 01 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,565 | $12,000 | Implemented |
MA0154 # 02 Y:1989 | 02 | 1989 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $882 | $2,892 | Implemented |
OR0058 # 01 Y:1989 | 01 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,281 | $0 | Implemented |
OR0058 # 02 Y:1989 | 02 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,976 | $200 | Implemented |
OR0058 # 04 Y:1989 | 04 | 1989 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,914 | $200 | Implemented |
OR0058 # 07 Y:1989 | 07 | 1989 | COVER OPEN TANKS | $1,428 | $0 | Implemented |
OR0058 # 08 Y:1989 | 08 | 1989 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $847 | $1,170 | Implemented |
TN0367 # 04 Y:1989 | 04 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,986 | $14,400 | Implemented |
TN0367 # 05 Y:1989 | 05 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,618 | $510 | Implemented |
TN0367 # 06 Y:1989 | 06 | 1989 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $6,876 | $20,900 | Implemented |
TN0367 # 07 Y:1989 | 07 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,338 | $0 | Implemented |
TN0367 # 08 Y:1989 | 08 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,336 | $500 | Implemented |
TN0367 # 09 Y:1989 | 09 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $631 | $0 | Implemented |