Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,510

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0207 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $25,155 $12,500 Implemented
TN0207 # 02 Y:1984 02 1984 INSULATE BARE EQUIPMENT $18,357 $750 Implemented
TN0207 # 03 Y:1984 03 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,215 $21,000 Implemented
TN0207 # 04 Y:1984 04 1984 INSTALL SET-BACK TIMERS $645 $0 Implemented
OK0136 # 01 Y:1984 01 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $124 $0 Implemented
OK0136 # 02 Y:1984 02 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33 $92 Implemented
OK0136 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $80 $43 Implemented
OK0136 # 05 Y:1984 05 1984 INSULATE BARE EQUIPMENT $407 $300 Implemented
OK0128 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $34,347 $800 Implemented
OK0128 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $468 $972 Implemented
OK0128 # 04 Y:1984 04 1984 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,237 $650 Implemented
UD0119 # 01 Y:1984 01 1984 REVISE SMOKE CLEANUP FROM OPERATIONS $5,989 $1,000 Implemented
UD0119 # 02 Y:1984 02 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,135 $700 Implemented
UD0119 # 03 Y:1984 03 1984 REDESIGN PROCESS $683 $2,000 Implemented
UD0119 # 04 Y:1984 04 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $162 $700 Implemented
OK0110 # 06 Y:1983 06 1983 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $343 $80 Implemented
OK0110 # 07 Y:1983 07 1983 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $937 $181 Implemented
UD0088 # 01 Y:1983 01 1983 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,182 $0 Implemented
UD0088 # 02 Y:1983 02 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,951 $9,396 Implemented
UD0072 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,588 $581 Implemented
UD0072 # 03 Y:1983 03 1983 RECOVER WASTE HEAT FROM EQUIPMENT $6,416 $518 Implemented
UD0072 # 05 Y:1983 05 1983 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $174 $0 Implemented
UD0072 # 07 Y:1983 07 1983 UPGRADE OBSOLETE EQUIPMENT $17,289 $0 Implemented
UD0071 # 03 Y:1983 03 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,364 $3,680 Implemented
UD0070 # 02 Y:1982 02 1982 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $6,051 $10,000 Implemented