Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
492
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0031 # 08 Y:2002 | 08 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $36,439 | $18,900 | Not Implemented |
IC0031 # 09 Y:2002 | 09 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $96,700 | $195,000 | Not Implemented |
IC0031 # 10 Y:2002 | 10 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $49,201 | $45,000 | Not Implemented |
ND0361 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $695 | $100 | Implemented |
ND0361 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,270 | $6,930 | Not Implemented |
ND0361 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $606 | $750 | Not Implemented |
ND0361 # 04 Y:2000 | 04 | 2000 | INCREASE EFFICIENCY OF TRUCKS | $2,929 | $18,500 | Not Implemented |
ND0361 # 05 Y:2000 | 05 | 2000 | DEVELOP A REPAIR/REPLACE POLICY | $4,112 | $41,893 | Implemented |
ND0361 # 06 Y:2000 | 06 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,329 | $400 | Implemented |
ND0343 # 01 Y:2000 | 01 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $27,009 | $4,500 | Not Implemented |
ND0343 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,145 | $400 | Not Implemented |
ND0343 # 03 Y:2000 | 03 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $507 | $40 | Not Implemented |
ND0343 # 04 Y:2000 | 04 | 2000 | DEVELOP A REPAIR/REPLACE POLICY | $8,389 | $43,959 | Not Implemented |
ND0343 # 05 Y:2000 | 05 | 2000 | OPTIMIZE PLANT POWER FACTOR | $11,327 | $22,922 | Not Implemented |
ND0343 # 06 Y:2000 | 06 | 2000 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $-3,501 | $6,210 | Not Implemented |
ND0343 # 07 Y:2000 | 07 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $24,533 | $250 | Not Implemented |
ND0341 # 01 Y:1999 | 01 | 1999 | DEVELOP A REPAIR/REPLACE POLICY | $22,377 | $60,343 | Not Implemented |
ND0341 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $128 | $200 | Not Implemented |
ND0341 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $344 | $180 | Implemented |
ND0341 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3 | $300 | Not Implemented |
ND0341 # 05 Y:1999 | 05 | 1999 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,719 | $250 | Implemented |
ND0341 # 06 Y:1999 | 06 | 1999 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $-177 | $336 | Not Implemented |
ND0341 # 07 Y:1999 | 07 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $9,218 | $250 | Not Implemented |
ND0341 # 08 Y:1999 | 08 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $90,862 | $120,000 | Not Implemented |
ND0328 # 01 Y:1999 | 01 | 1999 | PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW | $12,717 | $27,395 | Implemented |