Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

197

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0423 # 03 Y:2008 03 2008 INSTALL TIMERS AND/OR THERMOSTATS $1,639 $150 Not Implemented
IA0423 # 01 Y:2008 01 2008 REPAIR AND ELIMINATE STEAM LEAKS $2,458 $617 Implemented
IA0423 # 06 Y:2008 06 2008 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $11,415 $18,345 Not Implemented
IA0422 # 01 Y:2008 01 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,946 $660 Implemented
IA0422 # 02 Y:2008 02 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,525 $15 Implemented
IA0422 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,191 $300 Implemented
IA0422 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,350 $0 Implemented
IA0422 # 10 Y:2008 10 2008 INSTALL OCCUPANCY SENSORS $1,310 $1,155 Not Implemented
IA0422 # 07 Y:2008 07 2008 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $1,379 $350 Not Implemented
IA0422 # 06 Y:2008 06 2008 INSULATE BARE EQUIPMENT $6,865 $6,165 Implemented
IA0422 # 11 Y:2008 11 2008 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $664 $250 Implemented
IA0422 # 09 Y:2008 09 2008 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $474 $143 Implemented
IA0422 # 05 Y:2008 05 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,261 $305 Implemented
IA0422 # 04 Y:2008 04 2008 RECOVER WASTE HEAT FROM EQUIPMENT $1,842 $2,300 Not Implemented
IA0422 # 12 Y:2008 12 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,301 $0 Implemented
IA0413 # 01 Y:2007 01 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,287 $500 Implemented
IA0413 # 09 Y:2007 09 2007 RECOVER WASTE HEAT FROM EQUIPMENT $1,640 $2,160 Not Implemented
IA0413 # 10 Y:2007 10 2007 COVER OPEN TANKS $3,772 $1,500 Not Implemented
IA0413 # 12 Y:2007 12 2007 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $31,051 $4,000 Implemented
IA0413 # 03 Y:2007 03 2007 RECOVER WASTE HEAT FROM EQUIPMENT $9,370 $1,650 Not Implemented
IA0413 # 04 Y:2007 04 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,311 $360 Implemented
IA0413 # 02 Y:2007 02 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,295 $20 Implemented
IA0413 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $620 $535 Implemented
IA0413 # 11 Y:2007 11 2007 INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM $677 $80 Implemented
IA0413 # 08 Y:2007 08 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,195 $2,135 Implemented