Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,321
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0194 # 04 Y:2001 | 04 | 2001 | ELIMINATE SHUTDOWNS OF CONTROLS DUE TO OVERHEATING | $90,700 | $25,200 | Not Implemented |
UM0194 # 05 Y:2001 | 05 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $37,925 | $132,000 | Not Implemented |
UM0194 # 06 Y:2001 | 06 | 2001 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,888 | $4,500 | Not Implemented |
UM0194 # 07 Y:2001 | 07 | 2001 | OPTIMIZE PLANT POWER FACTOR | $14,163 | $22,163 | Not Implemented |
MA0498 # 01 Y:2001 | 01 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,844 | $60,000 | Implemented |
MA0498 # 02 Y:2001 | 02 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $10,867 | $0 | Implemented |
MA0498 # 03 Y:2001 | 03 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,790 | $35,000 | Not Implemented |
MA0498 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,980 | $0 | Implemented |
MA0498 # 05 Y:2001 | 05 | 2001 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,300 | $13,000 | Implemented |
MA0498 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,132 | $25,540 | Implemented |
MA0498 # 07 Y:2001 | 07 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $808 | $2,000 | Not Implemented |
MA0498 # 08 Y:2001 | 08 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $228 | $45 | Implemented |
LM0020 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,625 | $869 | Not Implemented |
LM0020 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,709 | $0 | Implemented |
LM0020 # 03 Y:2001 | 03 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $81,101 | $150,000 | Not Implemented |
LM0020 # 04 Y:2001 | 04 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,792 | $11,800 | Not Implemented |
LM0020 # 05 Y:2001 | 05 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,575 | $300 | Implemented |
LM0020 # 06 Y:2001 | 06 | 2001 | MODIFY WORKLOAD | $201,115 | $1,000 | Implemented |
LM0020 # 07 Y:2001 | 07 | 2001 | MODIFY WORKLOAD | $12,653 | $1,199 | Not Implemented |
OK0616 # 01 Y:2001 | 01 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $447 | $2,790 | Not Implemented |
OK0616 # 02 Y:2001 | 02 | 2001 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,570 | $1,040 | Implemented |
OK0616 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $17,387 | $4,428 | Implemented |
OK0616 # 04 Y:2001 | 04 | 2001 | INSTALL COMMON HEADER ON COMPRESSORS | $11,108 | $7,010 | Not Implemented |
OK0616 # 05 Y:2001 | 05 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,001 | $25,778 | n/a |
OK0616 # 06 Y:2001 | 06 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,349 | $21,884 | Not Implemented |