Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
930
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0665 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,561 | $8,112 | Implemented |
UD0665 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,363 | $6,762 | Not Implemented |
UD0665 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,130 | $1,000 | Not Implemented |
UD0665 # 09 Y:2003 | 09 | 2003 | DISCONNECT BALLASTS | $790 | $45 | Implemented |
UD0665 # 10 Y:2003 | 10 | 2003 | COVER OPEN TANKS | $256 | $400 | Implemented |
UD0664 # 01 Y:2003 | 01 | 2003 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $115,000 | $1,000 | Not Implemented |
UD0664 # 02 Y:2003 | 02 | 2003 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $61,800 | $144,000 | Not Implemented |
UD0664 # 03 Y:2003 | 03 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $61,795 | $35,000 | Implemented |
UD0664 # 04 Y:2003 | 04 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $37,413 | $28,500 | n/a |
UD0664 # 05 Y:2003 | 05 | 2003 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $16,536 | $2,600 | Not Implemented |
UD0664 # 06 Y:2003 | 06 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,785 | $800 | Implemented |
UD0664 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,070 | $12,830 | Implemented |
UD0664 # 08 Y:2003 | 08 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,884 | $111 | Not Implemented |
UD0664 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,630 | $5,820 | Not Implemented |
UD0664 # 10 Y:2003 | 10 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,280 | $378 | Not Implemented |
UD0664 # 11 Y:2003 | 11 | 2003 | DISCONNECT BALLASTS | $2,820 | $250 | Implemented |
UD0664 # 12 Y:2003 | 12 | 2003 | INSULATE BARE EQUIPMENT | $1,414 | $1,800 | Not Implemented |
UD0664 # 13 Y:2003 | 13 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,219 | $0 | Not Implemented |
UD0664 # 14 Y:2003 | 14 | 2003 | IMPROVE COMBUSTION CONTROL CAPABILITY | $247 | $25 | Not Implemented |
UD0664 # 15 Y:2003 | 15 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $178 | $0 | Implemented |
UD0664 # 16 Y:2003 | 16 | 2003 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $112 | $0 | Not Implemented |
WV0253 # 01 Y:2002 | 01 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,975 | $1,800 | Implemented |
WV0253 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $9,591 | $600 | Implemented |
WV0253 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,713 | $250 | Implemented |
WV0253 # 04 Y:2002 | 04 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,800 | $40 | Implemented |