Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,364
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0163 # 04 Y:1999 | 04 | 1999 | USE OPTIMUM THICKNESS INSULATION | $11,267 | $1,408 | Not Implemented |
AR0163 # 05 Y:1999 | 05 | 1999 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $251,669 | $66,400 | Not Implemented |
AR0163 # 06 Y:1999 | 06 | 1999 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $3,065 | $225 | Not Implemented |
TN0661 # 01 Y:1999 | 01 | 1999 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $175,335 | $5,000 | Implemented |
TN0661 # 02 Y:1999 | 02 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $91,400 | $49,760 | Not Implemented |
TN0661 # 03 Y:1999 | 03 | 1999 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $73,031 | $8,750 | Not Implemented |
TN0661 # 04 Y:1999 | 04 | 1999 | OPTIMIZE PLANT POWER FACTOR | $72,160 | $93,000 | Not Implemented |
TN0661 # 05 Y:1999 | 05 | 1999 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $39,290 | $2,720 | Not Implemented |
TN0661 # 06 Y:1999 | 06 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $25,103 | $30,600 | Implemented |
TN0661 # 07 Y:1999 | 07 | 1999 | METER WASTE WATER | $13,500 | $3,700 | Not Implemented |
TN0661 # 08 Y:1999 | 08 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $6,500 | $650 | Not Implemented |
UD0571 # 01 Y:1999 | 01 | 1999 | RECYCLE CASTING SAND | $227,844 | $135,000 | Implemented |
UD0571 # 02 Y:1999 | 02 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $67,000 | $24,000 | Not Implemented |
UD0571 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $27,700 | $40,000 | Not Implemented |
UD0571 # 04 Y:1999 | 04 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $21,000 | $64,000 | Implemented |
UD0571 # 05 Y:1999 | 05 | 1999 | CONVERT TO AQUEOUS CLEANING SYSTEM | $18,667 | $0 | Not Implemented |
UD0571 # 06 Y:1999 | 06 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,800 | $0 | Not Implemented |
UD0571 # 07 Y:1999 | 07 | 1999 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $9,000 | $24,000 | Not Implemented |
UD0571 # 08 Y:1999 | 08 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,582 | $0 | Implemented |
UD0571 # 09 Y:1999 | 09 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,489 | $0 | Not Implemented |
DS0141 # 01 Y:1999 | 01 | 1999 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $10,285 | $24,040 | Implemented |
DS0141 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $4,260 | $4,500 | Implemented |
DS0141 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,031 | $700 | Implemented |
DS0141 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,348 | $900 | Implemented |
DS0141 # 05 Y:1999 | 05 | 1999 | UPGRADE OBSOLETE EQUIPMENT | $13,679 | $32,000 | Implemented |