Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,364
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0184 # 01 Y:1997 | 01 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,231 | $59,862 | Not Implemented |
UL0184 # 02 Y:1997 | 02 | 1997 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $9,676 | $22,454 | Not Implemented |
UL0184 # 03 Y:1997 | 03 | 1997 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $5,672 | $90,000 | Not Implemented |
UL0184 # 04 Y:1997 | 04 | 1997 | USE OPTIMUM THICKNESS INSULATION | $25,680 | $14,000 | Not Implemented |
UL0184 # 05 Y:1997 | 05 | 1997 | OPTIMIZE PLANT POWER FACTOR | $6,000 | $9,270 | Implemented |
UL0184 # 06 Y:1997 | 06 | 1997 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $10,630 | $20,000 | Not Implemented |
UL0184 # 07 Y:1997 | 07 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,146 | $0 | Implemented |
UL0184 # 08 Y:1997 | 08 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,090 | $1,200 | Implemented |
UL0184 # 09 Y:1997 | 09 | 1997 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $4,400 | $0 | Not Implemented |
UL0184 # 10 Y:1997 | 10 | 1997 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $21,700 | $18,000 | Not Implemented |
UL0184 # 11 Y:1997 | 11 | 1997 | AUTOMATE FINISHING PROCESS | $315,748 | $222,000 | Implemented |
UL0184 # 12 Y:1997 | 12 | 1997 | DEVELOP STANDARD OPERATING PROCEDURES | $110,952 | $61,340 | Not Implemented |
UL0184 # 13 Y:1997 | 13 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $21,714 | $4,200 | Implemented |
AS0208 # 01 Y:1997 | 01 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,162 | $2,895 | Implemented |
AS0208 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,087 | $8,920 | Implemented |
AS0208 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $796 | $1,575 | Not Implemented |
AS0208 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,864 | $8,680 | Not Implemented |
AS0208 # 05 Y:1997 | 05 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,343 | $40,705 | Not Implemented |
AS0208 # 06 Y:1997 | 06 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $15,546 | $16,449 | Implemented |
AS0208 # 07 Y:1997 | 07 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $21,613 | $12,000 | Implemented |
AS0208 # 08 Y:1997 | 08 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $1,522 | $500 | Implemented |
AS0208 # 09 Y:1997 | 09 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $47,154 | $38,923 | Implemented |
AS0208 # 10 Y:1997 | 10 | 1997 | ADOPT IN-HOUSE MATERIAL GENERATION | $6,013 | $1,500 | Implemented |
AS0208 # 11 Y:1997 | 11 | 1997 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $11,210 | $100 | Implemented |
WI0302 # 01 Y:1997 | 01 | 1997 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $285,742 | $770,000 | Not Implemented |