Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
345
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0877 # 09 Y:2014 | 09 | 2014 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $2,159 | $1,600 | Implemented |
OK0877 # 08 Y:2014 | 08 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $487 | $1,834 | Not Implemented |
OK0877 # 07 Y:2014 | 07 | 2014 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $700 | $120 | Not Implemented |
OK0877 # 06 Y:2014 | 06 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $52 | $30 | Implemented |
OK0877 # 05 Y:2014 | 05 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,810 | $4,000 | Not Implemented |
OK0877 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $652 | $3,540 | Implemented |
OK0877 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,460 | $2,969 | Not Implemented |
OK0877 # 02 Y:2014 | 02 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,223 | $1,540 | Not Implemented |
OK0877 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,245 | $0 | Implemented |
OK0850 # 12 Y:2013 | 12 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,356 | $14,994 | Not Implemented |
OK0850 # 11 Y:2013 | 11 | 2013 | OPTIMIZE PLANT POWER FACTOR | $2,693 | $11,638 | Not Implemented |
OK0850 # 10 Y:2013 | 10 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $212 | $1,200 | Not Implemented |
OK0850 # 09 Y:2013 | 09 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $434 | $2,080 | Implemented |
OK0850 # 08 Y:2013 | 08 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $2,079 | $159 | Not Implemented |
OK0850 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $126 | $654 | Not Implemented |
OK0850 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $594 | $2,670 | Not Implemented |
OK0850 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,925 | $14,793 | Not Implemented |
OK0850 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $906 | $337 | Implemented |
OK0850 # 03 Y:2013 | 03 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $123 | $307 | Not Implemented |
OK0850 # 02 Y:2013 | 02 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $500 | $451 | Not Implemented |
OK0850 # 01 Y:2013 | 01 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,313 | $16,254 | Not Implemented |
OK0819 # 05 Y:2012 | 05 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $15,206 | $29,250 | Implemented |
OK0819 # 01 Y:2012 | 01 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,728 | $10,884 | Not Implemented |
OK0819 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,891 | $16,296 | Not Implemented |
OK0819 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $199 | $556 | Implemented |