Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,344
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0032 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $549 | $3,710 | Implemented |
SD0032 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $5,950 | $200 | Implemented |
SD0032 # 03 Y:1992 | 03 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,288 | $1,510 | Not Implemented |
SD0032 # 04 Y:1992 | 04 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,038 | $0 | Implemented |
SD0032 # 05 Y:1992 | 05 | 1992 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $5,219 | $3,900 | Not Implemented |
SD0032 # 06 Y:1992 | 06 | 1992 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $138 | $374 | Not Implemented |
SD0032 # 07 Y:1992 | 07 | 1992 | INSULATE BARE EQUIPMENT | $68 | $172 | Not Implemented |
SD0032 # 08 Y:1992 | 08 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,350 | $1,020 | Implemented |
SD0032 # 09 Y:1992 | 09 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $2,987 | $4,750 | Not Implemented |
SD0032 # 10 Y:1992 | 10 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,664 | $930 | Not Implemented |
SD0032 # 11 Y:1992 | 11 | 1992 | INSTALL SET-BACK TIMERS | $855 | $818 | Not Implemented |
AM0164 # 01 Y:1992 | 01 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $93,089 | $0 | Implemented |
AM0164 # 02 Y:1992 | 02 | 1992 | OPTIMIZE PLANT POWER FACTOR | $44,815 | $64,750 | Implemented |
AM0164 # 03 Y:1992 | 03 | 1992 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $19,440 | $850 | Not Implemented |
AM0164 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,158 | $1,030 | Implemented |
AM0164 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,200 | $419 | Not Implemented |
AM0164 # 06 Y:1992 | 06 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,140 | $910 | Implemented |
ND0045 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,000 | $25,240 | Implemented |
ND0045 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,840 | $579 | Implemented |
ND0045 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,324 | $1,000 | Implemented |
ND0045 # 04 Y:1992 | 04 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,874 | $1,000 | Not Implemented |
ND0045 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29 | $44 | Implemented |
KU0378 # 01 Y:1992 | 01 | 1992 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $29,220 | $100,000 | Not Implemented |
KU0378 # 02 Y:1992 | 02 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $21,344 | $0 | Not Implemented |
KU0378 # 03 Y:1992 | 03 | 1992 | OPTIMIZE PLANT POWER FACTOR | $10,253 | $6,000 | Not Implemented |