Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,344
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0007 # 03 Y:1991 | 03 | 1991 | COVER OPEN TANKS | $1,377 | $600 | Implemented |
SD0007 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $464 | $600 | Implemented |
SD0007 # 05 Y:1991 | 05 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $560 | $660 | Implemented |
SD0007 # 06 Y:1991 | 06 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $1,864 | $6,280 | Implemented |
SD0007 # 07 Y:1991 | 07 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $213 | $160 | Implemented |
SD0007 # 08 Y:1991 | 08 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $61 | $78 | Implemented |
MA0218 # 01 Y:1991 | 01 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,047 | $51,400 | Implemented |
MA0218 # 02 Y:1991 | 02 | 1991 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $14,649 | $15,470 | Implemented |
MA0218 # 03 Y:1991 | 03 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,973 | $724 | Implemented |
MA0218 # 04 Y:1991 | 04 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,981 | $726 | Implemented |
MA0218 # 05 Y:1991 | 05 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $753 | $0 | Implemented |
MA0218 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,262 | $15,300 | Implemented |
OR0120 # 01 Y:1991 | 01 | 1991 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $3,060 | $2,900 | Not Implemented |
OR0120 # 02 Y:1991 | 02 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,938 | $3,000 | Not Implemented |
OR0120 # 03 Y:1991 | 03 | 1991 | OPTIMIZE PLANT POWER FACTOR | $1,000 | $1,425 | Not Implemented |
OR0120 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $113 | $226 | Not Implemented |
OR0120 # 05 Y:1991 | 05 | 1991 | INSULATE BARE EQUIPMENT | $50 | $1,095 | Not Implemented |
MA0217 # 01 Y:1991 | 01 | 1991 | BURN A LESS EXPENSIVE GRADE OF FUEL | $51,002 | $4,050 | Not Implemented |
MA0217 # 02 Y:1991 | 02 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,862 | $19,305 | Not Implemented |
MA0217 # 03 Y:1991 | 03 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,453 | $1,500 | Not Implemented |
MA0217 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,357 | $30,000 | Not Implemented |
MA0217 # 05 Y:1991 | 05 | 1991 | REDUCE FLUID FLOW RATES | $8,252 | $330 | Not Implemented |
MA0217 # 06 Y:1991 | 06 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,199 | $0 | Not Implemented |
MA0217 # 07 Y:1991 | 07 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,777 | $3,874 | Not Implemented |
MA0217 # 08 Y:1991 | 08 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,370 | $0 | Not Implemented |