Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
230
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0192 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,610 | $6,030 | Not Implemented |
LL0192 # 07 Y:2004 | 07 | 2004 | INSULATE BARE EQUIPMENT | $2,881 | $911 | Not Implemented |
LL0192 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $3,529 | $720 | Not Implemented |
LL0192 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,708 | $2,585 | Implemented |
LL0192 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $21,326 | $420 | Not Implemented |
LL0192 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $41,577 | $4,400 | Implemented |
LL0192 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $55,907 | $0 | Not Implemented |
LL0192 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $61,254 | $2,590 | Implemented |
MS0204 # 01 Y:2002 | 01 | 2002 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $97,931 | $34,200 | Not Implemented |
MS0204 # 02 Y:2002 | 02 | 2002 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $10,266 | $5,760 | Not Implemented |
MS0204 # 03 Y:2002 | 03 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,500 | $3,763 | Not Implemented |
MS0204 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,399 | $331 | Not Implemented |
MS0204 # 05 Y:2002 | 05 | 2002 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $3,771 | $1,000 | Not Implemented |
MS0204 # 06 Y:2002 | 06 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $1,549 | $2,030 | Not Implemented |
MS0204 # 07 Y:2002 | 07 | 2002 | DISCONNECT BALLASTS | $129 | $256 | Implemented |
MS0204 # 08 Y:2002 | 08 | 2002 | PAY BILLS ON TIME TO AVOID LATE FEES | $89 | $25 | Implemented |
OK0616 # 05 Y:2001 | 05 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,001 | $25,778 | n/a |
OK0616 # 01 Y:2001 | 01 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $447 | $2,790 | Not Implemented |
OK0616 # 02 Y:2001 | 02 | 2001 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,570 | $1,040 | Implemented |
OK0616 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $17,387 | $4,428 | Implemented |
OK0616 # 04 Y:2001 | 04 | 2001 | INSTALL COMMON HEADER ON COMPRESSORS | $11,108 | $7,010 | Not Implemented |
OK0616 # 06 Y:2001 | 06 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,349 | $21,884 | Not Implemented |
OK0616 # 09 Y:2001 | 09 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $135,553 | $58,580 | n/a |
OK0616 # 10 Y:2001 | 10 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $540,000 | $125,040 | Implemented |
OK0616 # 07 Y:2001 | 07 | 2001 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,930,557 | $208,000 | n/a |