Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
180
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0251 # 04 Y:1995 | 04 | 1995 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $145,120 | $1,495,000 | Not Implemented |
OR0246 # 01 Y:1995 | 01 | 1995 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $12,000 | $19,000 | Not Implemented |
OR0246 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,521 | $6,281 | Implemented |
OR0246 # 03 Y:1995 | 03 | 1995 | MINIMIZE WATER USAGE | $3,070 | $0 | Implemented |
OR0246 # 04 Y:1995 | 04 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $122,760 | $205,000 | Implemented |
OR0246 # 05 Y:1995 | 05 | 1995 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $2,530 | $6,500 | Implemented |
OR0246 # 06 Y:1995 | 06 | 1995 | OPTIMIZE PLANT POWER FACTOR | $5,000 | $14,000 | Not Implemented |
OR0244 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,764 | $14,938 | Implemented |
OR0244 # 02 Y:1995 | 02 | 1995 | UPGRADE CONTROLS ON COMPRESSORS | $1,725 | $200 | Implemented |
OR0244 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $700 | $1,195 | Implemented |
OR0244 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $14,400 | $5,385 | Not Implemented |
OR0242 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,846 | $20,911 | Implemented |
OR0242 # 02 Y:1995 | 02 | 1995 | UPGRADE CONTROLS ON COMPRESSORS | $5,468 | $200 | Implemented |
OR0242 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,005 | $2,912 | Implemented |
OR0242 # 04 Y:1995 | 04 | 1995 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $2,587 | $3,400 | Implemented |
OR0242 # 05 Y:1995 | 05 | 1995 | OPTIMIZE PLANT POWER FACTOR | $1,971 | $6,800 | Not Implemented |
OR0242 # 06 Y:1995 | 06 | 1995 | IMPROVE COMBUSTION CONTROL CAPABILITY | $89,600 | $225,000 | Not Implemented |
OR0242 # 07 Y:1995 | 07 | 1995 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $22,000 | $1,000 | Not Implemented |
OR0242 # 08 Y:1995 | 08 | 1995 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $140,600 | $168,000 | Not Implemented |
OR0242 # 09 Y:1995 | 09 | 1995 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $157,000 | $1,200 | Implemented |
OR0216 # 01 Y:1994 | 01 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,306 | $797 | Not Implemented |
OR0216 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,327 | $4,643 | Not Implemented |
OR0216 # 03 Y:1994 | 03 | 1994 | USE PHOTOCELL CONTROLS | $1,499 | $2,210 | Not Implemented |
OR0216 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $45 | $286 | Not Implemented |
OR0216 # 05 Y:1994 | 05 | 1994 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $35,138 | $0 | Not Implemented |