Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

259

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0200 # 04 Y:1998 04 1998 INSULATE BARE EQUIPMENT $661 $1,128 Not Implemented
UL0200 # 05 Y:1998 05 1998 OPTIMIZE PLANT POWER FACTOR $8,870 $2,300 Not Implemented
UL0200 # 06 Y:1998 06 1998 USE BUILDING MATERIALS WHICH REQUIRE LESS ENERGY TO PRODUCE $45,190 $106,250 Not Implemented
UL0200 # 07 Y:1998 07 1998 RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE $19,940 $90,000 Not Implemented
UL0200 # 08 Y:1998 08 1998 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME $1,000,000 $102,500 Not Implemented
UL0200 # 09 Y:1998 09 1998 ADD ADDITIONAL PRODUCTION SHIFT $21,000 $10,000 Not Implemented
UL0184 # 01 Y:1997 01 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $31,231 $59,862 Not Implemented
UL0184 # 02 Y:1997 02 1997 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $9,676 $22,454 Not Implemented
UL0184 # 03 Y:1997 03 1997 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $5,672 $90,000 Not Implemented
UL0184 # 04 Y:1997 04 1997 USE OPTIMUM THICKNESS INSULATION $25,680 $14,000 Not Implemented
UL0184 # 05 Y:1997 05 1997 OPTIMIZE PLANT POWER FACTOR $6,000 $9,270 Implemented
UL0184 # 06 Y:1997 06 1997 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $10,630 $20,000 Not Implemented
UL0184 # 07 Y:1997 07 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $4,146 $0 Implemented
UL0184 # 08 Y:1997 08 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,090 $1,200 Implemented
UL0184 # 09 Y:1997 09 1997 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $4,400 $0 Not Implemented
UL0184 # 10 Y:1997 10 1997 USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL $21,700 $18,000 Not Implemented
UL0184 # 11 Y:1997 11 1997 AUTOMATE FINISHING PROCESS $315,748 $222,000 Implemented
UL0184 # 12 Y:1997 12 1997 DEVELOP STANDARD OPERATING PROCEDURES $110,952 $61,340 Not Implemented
UL0184 # 13 Y:1997 13 1997 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $21,714 $4,200 Implemented
UL0183 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,385 $2,200 Implemented
UL0183 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $151 $2,700 Not Implemented
UL0183 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,200 $260 Not Implemented
UL0183 # 04 Y:1997 04 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $11,650 $40 Not Implemented
UL0183 # 05 Y:1997 05 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $40,200 $82,600 Not Implemented
UL0183 # 06 Y:1997 06 1997 CLEAR AND RENT EXISTING SPACE $130,000 $2,400 Implemented