Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
488
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0329 # 03 Y:2003 | 03 | 2003 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $11,417 | $0 | n/a |
UF0329 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,931 | $0 | n/a |
UF0329 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $27,383 | $370 | n/a |
UF0329 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,754 | $13,170 | n/a |
UF0329 # 07 Y:2003 | 07 | 2003 | IMPROVE PROCESS CONTROL TO PREVENT SPILLS OF MATERIAL | $85,198 | $48,000 | n/a |
UF0329 # 08 Y:2003 | 08 | 2003 | RECYCLE CASTING SAND | $836,208 | $1,130,370 | n/a |
UF0329 # 09 Y:2003 | 09 | 2003 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $708,707 | $335,000 | n/a |
UF0329 # 10 Y:2003 | 10 | 2003 | $141,821 | $165,600 | n/a | |
UF0329 # 11 Y:2003 | 11 | 2003 | $1,192 | $2,675 | n/a | |
UD0678 # 01 Y:2003 | 01 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $57,760 | $0 | Implemented |
UD0678 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,800 | $78,325 | Not Implemented |
UD0678 # 03 Y:2003 | 03 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,500 | $980 | Implemented |
UD0678 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,900 | $725 | Implemented |
UD0678 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,840 | $0 | Implemented |
UD0678 # 06 Y:2003 | 06 | 2003 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $6,015 | $3,150 | Not Implemented |
UD0678 # 07 Y:2003 | 07 | 2003 | USE OPTIMUM TEMPERATURE | $5,406 | $500 | Not Implemented |
UD0678 # 08 Y:2003 | 08 | 2003 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $4,745 | $2,400 | Implemented |
UD0678 # 09 Y:2003 | 09 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $2,654 | $1,000 | Implemented |
UD0678 # 10 Y:2003 | 10 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,251 | $2,000 | Implemented |
UD0678 # 11 Y:2003 | 11 | 2003 | DISCONNECT BALLASTS | $1,865 | $90 | Implemented |
IC0065 # 02 Y:2003 | 02 | 2003 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $243,209 | $1,400,000 | Implemented |
IC0065 # 03 Y:2003 | 03 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,757 | $516 | Implemented |
IC0065 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,168 | $68,925 | Not Implemented |
IC0065 # 05 Y:2003 | 05 | 2003 | $189,440 | $29,000 | Not Implemented | |
IC0065 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,360 | $13,999 | Implemented |