Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
561
matching recommendationsSIC | 3312 | Blast Furnaces And Steel Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0065 # 03 Y:2003 | 03 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,757 | $516 | Implemented |
IC0065 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,168 | $68,925 | Not Implemented |
IC0065 # 05 Y:2003 | 05 | 2003 | AUTOMATE FINISHING PROCESS | $189,440 | $29,000 | Not Implemented |
IC0065 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,360 | $13,999 | Implemented |
IC0065 # 07 Y:2003 | 07 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,611 | $3,488 | Not Implemented |
SU0141 # 01 Y:2002 | 01 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,663,245 | $4,336,000 | Not Implemented |
SU0141 # 02 Y:2002 | 02 | 2002 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $640,000 | $9,000,000 | Implemented |
SU0141 # 03 Y:2002 | 03 | 2002 | CONSOLIDATE FREIGHT SHIPMENTS AND/OR DELIVERIES | $522,000 | $4,077,000 | Not Implemented |
SU0141 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $117,834 | $95,000 | Implemented |
SU0141 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $55,317 | $203,719 | Implemented |
SU0141 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $33,774 | $0 | Not Implemented |
SU0141 # 07 Y:2002 | 07 | 2002 | OPTIMIZE PLANT POWER FACTOR | $17,677 | $84,000 | Not Implemented |
SU0141 # 08 Y:2002 | 08 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,012 | $480 | Implemented |
SU0141 # 09 Y:2002 | 09 | 2002 | INSTALL OCCUPANCY SENSORS | $2,155 | $1,110 | Implemented |
NC0241 # 01 Y:2002 | 01 | 2002 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $6,456 | $8,000 | Implemented |
NC0241 # 02 Y:2002 | 02 | 2002 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,506 | $6,000 | Not Implemented |
NC0241 # 03 Y:2002 | 03 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $4,751 | $6,493 | Implemented |
NC0241 # 04 Y:2002 | 04 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $503 | $576 | Not Implemented |
NC0241 # 05 Y:2002 | 05 | 2002 | KEEP BOILER TUBES CLEAN | $499 | $1,600 | Implemented |
WI0421 # 01 Y:2002 | 01 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,343 | $1,400 | Not Implemented |
WI0421 # 02 Y:2002 | 02 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,154 | $2,688 | Not Implemented |
WI0421 # 03 Y:2002 | 03 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $4,470 | $600 | Implemented |
WI0421 # 04 Y:2002 | 04 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,940 | $500 | Implemented |
WI0421 # 05 Y:2002 | 05 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,752 | $8,000 | Not Implemented |
LL0119 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $22,921 | $4,950 | Implemented |