IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

52

matching recommendations
Reset
SIC 3312 Blast Furnaces And Steel Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0808 # 25 Y:2009 25 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,670 $0 Not Implemented
UD0808 # 09 Y:2009 09 2009 COVER OPEN TANKS $25,313 $0 Not Implemented
UD0808 # 08 Y:2009 08 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $43,197 $23,136 Not Implemented
UD0808 # 07 Y:2009 07 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $43,538 $59,100 Not Implemented
UD0808 # 06 Y:2009 06 2009 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $67,977 $135,954 Not Implemented
UD0808 # 05 Y:2009 05 2009 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $68,888 $60,000 Not Implemented
UD0808 # 04 Y:2009 04 2009 OPTIMIZE PLANT POWER FACTOR $74,208 $223,000 Not Implemented
UD0808 # 03 Y:2009 03 2009 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $95,164 $300,000 Not Implemented
UD0808 # 02 Y:2009 02 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $108,914 $25,000 Not Implemented
UD0808 # 01 Y:2009 01 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $200,411 $425,000 Not Implemented
UD0808 # 11 Y:2009 11 2009 MODERATE COOLING TOWER OUTLET TEMPERATURE $18,970 $20,000 Not Implemented
UM0102 # 05 Y:1998 05 1998 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $429 $160 Implemented
UM0102 # 04 Y:1998 04 1998 RECOVER AND REUSE WASTE MATERIAL $8,280 $250 Not Implemented
UM0102 # 03 Y:1998 03 1998 INSTALL SKYLIGHTS $562 $1,288 Not Implemented
UM0102 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,544 $5,431 Not Implemented
UM0102 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $334 $583 Implemented
UM0102 # 06 Y:1998 06 1998 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $37,187 $8,400 Not Implemented
UD0337 # 01 Y:1991 01 1991 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $69,034 $0 Not Implemented
UD0337 # 02 Y:1991 02 1991 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $37,108 $90,000 Not Implemented
UD0337 # 03 Y:1991 03 1991 INSULATE BARE EQUIPMENT $3,239 $2,700 Not Implemented
UD0337 # 04 Y:1991 04 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,619 $0 Not Implemented
UD0337 # 05 Y:1991 05 1991 INSTALL SET-BACK TIMERS $1,077 $0 Not Implemented
UD0337 # 06 Y:1991 06 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $45,840 $0 Not Implemented
UD0333 # 03 Y:1991 03 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,976 $0 Implemented
UD0333 # 02 Y:1991 02 1991 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $145,812 $0 Implemented