Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

661

matching recommendations
Reset
SIC 3315 Steel Wire And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0961 # 06 Y:2017 06 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $831 $3,220 Not Implemented
OK0961 # 07 Y:2017 07 2017 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $216,378 $7,000 Not Implemented
OK0961 # 08 Y:2017 08 2017 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $12,104 $792 Not Implemented
OK0961 # 09 Y:2017 09 2017 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $50,374 $124,000 Not Implemented
OK0961 # 10 Y:2017 10 2017 COVER OPEN TANKS $27,427 $3,900 Not Implemented
OK0961 # 11 Y:2017 11 2017 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $44,544 $8,817 Not Implemented
OK0961 # 12 Y:2017 12 2017 REUSE RICH WHITE WATER IN OTHER APPLICATIONS $523,580 $500,000 Not Implemented
OK0961 # 13 Y:2017 13 2017 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $311,801 $1,832,665 Not Implemented
OK0961 # 14 Y:2017 14 2017 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $497,839 $3,000,000 Not Implemented
SD0536 # 06 Y:2016 06 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,995 $648 Implemented
SD0536 # 01 Y:2016 01 2016 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $91,093 $350,298 Not Implemented
SD0536 # 02 Y:2016 02 2016 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $23,163 $68,259 Not Implemented
SD0536 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,468 $8,787 Not Implemented
SD0536 # 04 Y:2016 04 2016 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $6,259 $11,760 Not Implemented
SD0536 # 05 Y:2016 05 2016 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,594 $11,180 Not Implemented
SD0536 # 07 Y:2016 07 2016 USE PHOTOCELL CONTROLS $2,367 $3,700 Not Implemented
SD0536 # 08 Y:2016 08 2016 INSULATE BARE EQUIPMENT $1,796 $2,742 Implemented
SD0536 # 09 Y:2016 09 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,472 $200 Not Implemented
SD0536 # 10 Y:2016 10 2016 INSTALL OCCUPANCY SENSORS $1,296 $3,200 Implemented
SD0536 # 11 Y:2016 11 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,278 $1,200 Implemented
LE0413 # 08 Y:2016 08 2016 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,559 $14,000 Not Implemented
LE0413 # 07 Y:2016 07 2016 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,462 $25,000 Implemented
LE0413 # 06 Y:2016 06 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,404 $15,000 Implemented
LE0413 # 05 Y:2016 05 2016 INSTALL TIMERS AND/OR THERMOSTATS $482 $590 Implemented
LE0413 # 04 Y:2016 04 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $973 $1,000 Implemented