Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
661
matching recommendationsSIC | 3315 | Steel Wire And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0154 # 09 Y:2009 | 09 | 2009 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $725 | $1,126 | Not Implemented |
IC0154 # 10 Y:2009 | 10 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,269 | $0 | Not Implemented |
IC0154 # 11 Y:2009 | 11 | 2009 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $2,094 | $0 | Not Implemented |
UF0417 # 02 Y:2008 | 02 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,012 | $0 | Implemented |
UF0417 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,847 | $36,441 | Not Implemented |
UF0417 # 10 Y:2008 | 10 | 2008 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $45,096 | $15,000 | Not Implemented |
UF0417 # 09 Y:2008 | 09 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $65,568 | $31,410 | Not Implemented |
UF0417 # 08 Y:2008 | 08 | 2008 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $3,201 | $1,200 | Not Implemented |
UF0417 # 07 Y:2008 | 07 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $19,601 | $64,339 | Not Implemented |
UF0417 # 06 Y:2008 | 06 | 2008 | INSTALL COMMON HEADER ON COMPRESSORS | $12,647 | $900 | Not Implemented |
UF0417 # 05 Y:2008 | 05 | 2008 | INSTALL COMMON HEADER ON COMPRESSORS | $14,617 | $0 | Not Implemented |
UF0417 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,992 | $0 | Implemented |
UF0417 # 03 Y:2008 | 03 | 2008 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $10,710 | $0 | Implemented |
UF0417 # 11 Y:2008 | 11 | 2008 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,200 | $4,158 | Not Implemented |
IC0120 # 01 Y:2006 | 01 | 2006 | RECOVER AND REUSE SPENT ACID BATHS | $132,386 | $176,160 | Implemented |
IC0120 # 02 Y:2006 | 02 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $916 | $0 | Implemented |
IC0120 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,452 | $8,047 | Implemented |
IC0120 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,943 | $1,300 | Implemented |
IC0120 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $447 | $911 | Implemented |
IC0120 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $586 | $639 | Not Implemented |
IC0120 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,533 | $18,187 | Implemented |
IC0120 # 08 Y:2006 | 08 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $29,735 | $76,800 | Not Implemented |
IC0120 # 09 Y:2006 | 09 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $114,144 | $385,200 | Implemented |
IC0120 # 10 Y:2006 | 10 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $991 | $7,638 | Not Implemented |
IC0120 # 11 Y:2006 | 11 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $71,667 | $6,720 | Implemented |