Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 3316 | Cold Finishing Of Steel Shapes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0200 # 09 Y:1998 | 09 | 1998 | ADD ADDITIONAL PRODUCTION SHIFT | $21,000 | $10,000 | Not Implemented |
UL0200 # 08 Y:1998 | 08 | 1998 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $1,000,000 | $102,500 | Not Implemented |
UL0200 # 07 Y:1998 | 07 | 1998 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $19,940 | $90,000 | Not Implemented |
UL0200 # 06 Y:1998 | 06 | 1998 | USE BUILDING MATERIALS WHICH REQUIRE LESS ENERGY TO PRODUCE | $45,190 | $106,250 | Not Implemented |
UL0200 # 05 Y:1998 | 05 | 1998 | OPTIMIZE PLANT POWER FACTOR | $8,870 | $2,300 | Not Implemented |
UL0200 # 04 Y:1998 | 04 | 1998 | INSULATE BARE EQUIPMENT | $661 | $1,128 | Not Implemented |
UL0200 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,112 | $200 | Not Implemented |
UL0200 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $647 | $400 | Not Implemented |
UL0200 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,608 | $6,654 | Not Implemented |
DS0118 # 02 Y:1998 | 02 | 1998 | OPTIMIZE PLANT POWER FACTOR | $610 | $600 | Implemented |
DS0118 # 05 Y:1998 | 05 | 1998 | REVISE RAW MATERIAL SPECS | $2,372 | $0 | Not Implemented |
DS0118 # 04 Y:1998 | 04 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,400 | $2,200 | Not Implemented |
DS0118 # 03 Y:1998 | 03 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $3,300 | $160 | Not Implemented |
DS0118 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,578 | $5,326 | Implemented |
OD0110 # 03 Y:1998 | 03 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,397 | $605 | Implemented |
OD0110 # 02 Y:1998 | 02 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,307 | $10,032 | Implemented |
OD0110 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,812 | $8,363 | Implemented |
OD0110 # 04 Y:1998 | 04 | 1998 | REDUCE VENTILATION AIR | $1,460 | $1,100 | Implemented |
WV0133 # 13 Y:1998 | 13 | 1998 | EXPAND OPERATIONS INTO UNUSED SPACE | $11,375 | $2,520 | Implemented |
WV0133 # 12 Y:1998 | 12 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,600 | $0 | Implemented |
WV0133 # 11 Y:1998 | 11 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,796 | $11,000 | Not Implemented |
WV0133 # 10 Y:1998 | 10 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,372 | $7,000 | Implemented |
WV0133 # 09 Y:1998 | 09 | 1998 | USE RADIANT HEATER FOR SPOT HEATING | $18,727 | $350 | Not Implemented |
WV0133 # 08 Y:1998 | 08 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $72,430 | $100,440 | Implemented |
WV0133 # 07 Y:1998 | 07 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,854 | $1,210 | Not Implemented |