Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

26

matching recommendations
Reset
SIC 3317 Steel Pipe And Tubes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0476 # 08 Y:2004 08 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $308 $776 Not Implemented
WI0476 # 07 Y:2004 07 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,141 $640 Implemented
WI0476 # 06 Y:2004 06 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,148 $0 Implemented
WI0476 # 05 Y:2004 05 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,557 $4,280 Implemented
WI0476 # 04 Y:2004 04 2004 INSTALL OCCUPANCY SENSORS $5,082 $2,944 Not Implemented
WI0476 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,856 $8,856 Not Implemented
WI0476 # 02 Y:2004 02 2004 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $15,807 $21,000 Not Implemented
WI0476 # 01 Y:2004 01 2004 BURN WASTE OIL FOR HEAT $73,937 $36,000 Not Implemented
LL0192 # 02 Y:2004 02 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $55,907 $0 Not Implemented
LL0192 # 07 Y:2004 07 2004 INSULATE BARE EQUIPMENT $2,881 $911 Not Implemented
LL0192 # 06 Y:2004 06 2004 USE PHOTOCELL CONTROLS $3,529 $720 Not Implemented
LL0192 # 05 Y:2004 05 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,708 $2,585 Implemented
LL0192 # 04 Y:2004 04 2004 USE PHOTOCELL CONTROLS $21,326 $420 Not Implemented
LL0192 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $41,577 $4,400 Implemented
LL0192 # 01 Y:2004 01 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $61,254 $2,590 Implemented
LL0192 # 08 Y:2004 08 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $5,610 $6,030 Not Implemented
WV0291 # 10 Y:2004 10 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $550 $100 Implemented
WV0291 # 09 Y:2004 09 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $685 $747 Not Implemented
WV0291 # 08 Y:2004 08 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,485 $116 Not Implemented
WV0291 # 07 Y:2004 07 2004 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,519 $5,205 Not Implemented
WV0291 # 06 Y:2004 06 2004 INSTALL OCCUPANCY SENSORS $1,720 $1,316 Not Implemented
WV0291 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,186 $0 Implemented
WV0291 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,578 $4,824 Implemented
WV0291 # 03 Y:2004 03 2004 DEVELOP A REPAIR/REPLACE POLICY $6,488 $0 Implemented
WV0291 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,255 $1,032 Not Implemented