Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,069
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0730 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $150 | $767 | Implemented |
OK0730 # 06 Y:2006 | 06 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,565 | $8,601 | Not Implemented |
OK0730 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,886 | $1,767 | Implemented |
LM0118 # 01 Y:2006 | 01 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $8,571 | $10,004 | Not Implemented |
LM0118 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $969 | $2,578 | Not Implemented |
LM0118 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,104 | $425 | Implemented |
LM0118 # 04 Y:2006 | 04 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $5,931 | $0 | Not Implemented |
LE0214 # 01 Y:2005 | 01 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $3,742 | $30,000 | Not Implemented |
LE0214 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,637 | $5,500 | Implemented |
LE0214 # 03 Y:2005 | 03 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,017 | $320 | Implemented |
LE0214 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,291 | $640 | Not Implemented |
LE0214 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,259 | $2,300 | Implemented |
LE0214 # 06 Y:2005 | 06 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,575 | $500 | Implemented |
UM0277 # 01 Y:2005 | 01 | 2005 | REDUCE SCRAP PRODUCTION | $34,320 | $7,500 | Implemented |
UM0277 # 02 Y:2005 | 02 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,442 | $1,000 | Implemented |
UM0277 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,729 | $3,000 | Not Implemented |
UM0277 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,247 | $1,000 | Implemented |
LM0091 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $709 | $300 | Implemented |
LM0091 # 02 Y:2005 | 02 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,029 | $683 | Implemented |
LM0091 # 03 Y:2005 | 03 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $764 | $240 | Implemented |
LM0091 # 04 Y:2005 | 04 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $28,000 | $1,260 | Not Implemented |
LM0091 # 05 Y:2005 | 05 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $8,750 | $200 | Implemented |
LM0091 # 06 Y:2005 | 06 | 2005 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $16,875 | $2,150 | Implemented |
LM0091 # 07 Y:2005 | 07 | 2005 | MOVE PRODUCT USING MECHANICAL MEANS | $16,875 | $1,600 | Implemented |
UM0268 # 01 Y:2004 | 01 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,159 | $14,530 | Not Implemented |