IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,049

matching recommendations
Reset
SIC 332 Iron And Steel Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0177 # 01 Y:2001 01 2001 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $5,246 $11,850 Not Implemented
UM0177 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,577 $950 Implemented
UM0177 # 03 Y:2001 03 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $12,663 $4,200 Not Implemented
UM0177 # 04 Y:2001 04 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $12,480 $27,000 Implemented
UM0177 # 05 Y:2001 05 2001 RECOVER METALS FROM CASTING SAND $64,000 $0 Not Implemented
UM0177 # 06 Y:2001 06 2001 RECYCLE CASTING SAND $48,000 $0 Implemented
UM0177 # 07 Y:2001 07 2001 CONTRACT A WOOD PALLET RECYCLING COMPANY $14,000 $0 Implemented
OK0606 # 01 Y:2000 01 2000 $59,500 $115,187 Not Implemented
OK0606 # 02 Y:2000 02 2000 AIR CONDITION ONLY SPACE NECESSARY $291 $112 Implemented
OK0606 # 03 Y:2000 03 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $67 $66 Implemented
OK0606 # 04 Y:2000 04 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $596 $300 Implemented
OK0606 # 05 Y:2000 05 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,049 $0 Implemented
UM0173 # 01 Y:2000 01 2000 INSTALL OCCUPANCY SENSORS $573 $800 Not Implemented
UM0173 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,521 $225 Not Implemented
UM0173 # 03 Y:2000 03 2000 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $758 $700 Not Implemented
UM0173 # 04 Y:2000 04 2000 UPGRADE CONTROLS ON COMPRESSORS $3,506 $800 Not Implemented
UM0173 # 05 Y:2000 05 2000 RECOVER WASTE HEAT FROM EQUIPMENT $2,300 $750 Not Implemented
UD0608 # 01 Y:2000 01 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $27,415 $15,000 Implemented
UD0608 # 02 Y:2000 02 2000 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $13,231 $1,200 Implemented
UD0608 # 03 Y:2000 03 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,027 $6,250 Implemented
UD0608 # 04 Y:2000 04 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,480 $14,755 Implemented
UD0608 # 05 Y:2000 05 2000 RECOVER WASTE HEAT FROM EQUIPMENT $4,156 $3,500 Not Implemented
UD0608 # 06 Y:2000 06 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,103 $0 Not Implemented
UD0608 # 07 Y:2000 07 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,709 $4,624 Not Implemented
UM0169 # 01 Y:2000 01 2000 $15,444 $2,250 Implemented