Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
278
matching recommendationsSIC | 3324 | Steel Investment Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0280 # 03 Y:2009 | 03 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,445 | $0 | Implemented |
SU0280 # 04 Y:2009 | 04 | 2009 | USE SYNTHETIC LUBRICANT | $1,438 | $0 | Not Implemented |
SU0280 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,497 | $378 | Implemented |
SU0280 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $4,873 | $1,477 | Implemented |
SU0280 # 07 Y:2009 | 07 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,497 | $3,768 | Implemented |
SU0280 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $405 | Not Implemented |
SU0280 # 09 Y:2009 | 09 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $47,225 | $73,508 | Not Implemented |
SU0280 # 10 Y:2009 | 10 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $644 | $1,009 | Not Implemented |
SU0280 # 11 Y:2009 | 11 | 2009 | OPTIMIZE PLANT POWER FACTOR | $2,725 | $7,949 | Implemented |
UM0326 # 01 Y:2007 | 01 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $26,782 | $1,000 | Not Implemented |
UM0326 # 02 Y:2007 | 02 | 2007 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $8,825 | $13,130 | Implemented |
UM0326 # 03 Y:2007 | 03 | 2007 | COVER OPEN TANKS | $4,631 | $220 | Implemented |
UM0326 # 04 Y:2007 | 04 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,591 | $500 | Implemented |
UM0326 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,234 | $675 | Implemented |
UM0326 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,191 | $1,860 | Implemented |
UM0326 # 07 Y:2007 | 07 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,476 | $2,200 | Implemented |
UM0326 # 08 Y:2007 | 08 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,092 | $204 | Implemented |
UM0326 # 09 Y:2007 | 09 | 2007 | INSTALL OCCUPANCY SENSORS | $253 | $600 | Implemented |
SD0397 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $51,686 | $51,240 | Not Implemented |
SD0397 # 02 Y:2007 | 02 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $52,328 | $44,175 | Not Implemented |
SD0397 # 03 Y:2007 | 03 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,149 | $18,100 | Not Implemented |
SD0397 # 04 Y:2007 | 04 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,700 | $23,250 | Not Implemented |
SD0397 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,897 | $420 | Implemented |
SD0397 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,198 | $17,214 | Implemented |
SD0397 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,697 | $71,224 | Implemented |